M A G U I R E P R O D U C T S , I N C .
61
W E I G H S C A L E B L E N D E R
Parameters Introduction
All WEIGH SCALE BLENDER controllers operate according to certain internal PARAMETERS. Because customer
requirements vary widely, we have made over 160 parameters accessible for change through the keypad. There is
one GENERAL group and twelve COMPONENT groups.
BRIEF
explanations are given first.
FULL
information is given in the section that follows.
Parameters values shown here are initial ROM values of a model 940. Initial values for
other models are listed at the end of this section.
Parameters are five digits, with leading zeros added.
TIMES
TIMES are expressed as seconds, minutes, or interrupts.
(244 interrupts = 1 second).
WEIGHTS
are always expressed as GRAMS.
100 and 200 models use tenths of grams: (xxxx.x). (00010 = 1 gram)
400/900/1800/3000 models; full grams: (xxxxx). (00010 = 10 grams)
PERCENTS
are expressed in tenths for settings (0xxx.x), and full percents for other percentage
references (00xxx).
Navigating Parameters
In the COMPONENT lists:
The TOP parameter (TYPE) is ALWAYS accessible.
The others are NOT accessible unless TYPE is set onto a setting.
The First press of the PARA key will enter the GENERAL list at the top. Then the first press of the SET key will move
to top of the first component list. Press the PARA key to move down in any list.
While in one COMPONENT list, press the SET key to jump to the same relative position in the next list. This allows
rapid scanning of like parameters in all component groups.
To change a displayed parameter enter a new number in place of the old one. CE will cancel a number entry before
the last digit is entered. The purpose of each parameter is explained elsewhere in this manual.
In any component list, if TYPE is set to "OFF"; (_TY= OFF); other parameters in that list are not accessible.
EXIT will exit the sequence at any time.
Navigating Parameters Quickly - Keypad Sequence:
Press
To ENTER the list at the TOP LEFT (FLG)
Press
To move DOWN a list
Press
To move UP
Press
To move RIGHT (1st time, goes to 1TY)
Press
To move LEFT
Press
When finished EXIT will take you out of Parameters
Summary of Contents for Weigh Scale Blender
Page 17: ...M A G U I R E P R O D U C T S I N C 17 W E I G H S C A L E B L E N D E R...
Page 116: ...M A G U I R E P R O D U C T S I N C 116 W E I G H S C A L E B L E N D E R Technical Drawings...
Page 117: ...M A G U I R E P R O D U C T S I N C 117 W E I G H S C A L E B L E N D E R...
Page 118: ...M A G U I R E P R O D U C T S I N C 118 W E I G H S C A L E B L E N D E R...
Page 119: ...M A G U I R E P R O D U C T S I N C 119 W E I G H S C A L E B L E N D E R...
Page 120: ...M A G U I R E P R O D U C T S I N C 120 W E I G H S C A L E B L E N D E R...
Page 121: ...M A G U I R E P R O D U C T S I N C 121 W E I G H S C A L E B L E N D E R...
Page 122: ...M A G U I R E P R O D U C T S I N C 122 W E I G H S C A L E B L E N D E R...
Page 123: ...M A G U I R E P R O D U C T S I N C 123 W E I G H S C A L E B L E N D E R...
Page 124: ...M A G U I R E P R O D U C T S I N C 124 W E I G H S C A L E B L E N D E R...
Page 125: ...M A G U I R E P R O D U C T S I N C 125 W E I G H S C A L E B L E N D E R...
Page 126: ...M A G U I R E P R O D U C T S I N C 126 W E I G H S C A L E B L E N D E R...
Page 127: ...M A G U I R E P R O D U C T S I N C 127 W E I G H S C A L E B L E N D E R...
Page 136: ...M A G U I R E P R O D U C T S I N C 136 W E I G H S C A L E B L E N D E R...