M A G U I R E P R O D U C T S , I N C .
62
W E I G H S C A L E B L E N D E R
Press the
CE
key to toggle between DHCP and static IP Address.
Note:
If you plan to use DHCP be aware that software connecting to the Maguire Controller
typically requires a known IP address that does not change, therefore your DHCP server will most
likely need to maintain the same IP for the controller. To determine the controllers MAC address,
see *62.
Using a Static IP Address - Press the
CE
key to toggle between DHCP and static IP Address. When the
display toggles to Static IP, use the keypad to enter the static IP address you wish to assign the controller.
Use leading zeros and press the * key for decimal. After entering the IP, the display will go to Network
Mask (Subnet), then to Default Gateway. After entering the Default Gateway, the display will return to
Static IP. When you are finished entering the network information, press exit to save settings and exit
again to exit out of programming mode.
MLAN commands use TCP port 9999 (G2, OPC, MLAN).
WSB COMMUNICATIONS
– Sets the Blender ID number
Press (*,6,6) to enter an identification number for this particular weigh scale blender. This I.D. number will
appear on all printed reports. If you have more than one unit, this helps to identify reports. If you are using
a computer to automatically gather data, then each controller must have a unique address. Valid numbers
are 000 to 255. When connected to a computer, do not use the number 000 for identification.
MODBUS COMMUNICATIONS
– Enable / Disable
Press (*,6,7) to enable or disable Modbus communications.
Press "*" to toggle between
ENABLED
and
DISABLED
.
Press Exit when complete.
Modbus commands use TCP port 502.
Modbus
registers are available upon request or may be downloaded from our website.
ADD & COL AS % MIX - Special Applications Only
– Additive Percent of Mix
Press (*,7,2) to change the Additive settings to be interpreted as percent of the entire MIX instead of
percent of the Natural. The display will say
ADD & COL AS % MIX ENABLED or DISABLED
. Press "*"
to toggle flag between
ENABLED
and
DISABLED
. This option has been added for customers with unique
requirements.
Leave this flag OFF, (APM- OFF), unless you have specific instructions to do otherwise.
CAUTION
: With this flag set, additive settings combined must NOT exceed 100 percent. From a practical
standpoint, they should not exceed 10 percent combined.
MAX Weight Alarm
Press (*,7,4) to set a flag that will cause the system to stop and the Alarm to activate when MAX weight is
exceeded. This might occur if a valve sticks open or slightly open. Normally the system recovers
automatically from such events with only the one batch blended incorrectly. Set the flag only if you want
the system to stop and alarm.
Press * key to toggle between
ENABLED
and
DISABLED.
Press EXIT when done.
WEIGHT LOSS ALARM - Weight Reading Alarm
Press (*,7,5) to set a flag to ALARM if the weigh bin weight drops more them 20 grams during a cycle. This
serves to detect and report a weigh bin problem, such as material leaking from the bottom of the bin.
Press * key to toggle between
ENABLED
and
DISABLED.
Press EXIT when done.
Parameter Printout
Press (*,7,7) to write a copy of all internal parameters to a plain text file on a USB flash drive. A
folder named maguire must be present on the USB flash drive and the flash drive must be
plugged into the USB port of the controller. Up to 13 lists will print, a General list and 12
component lists. Only components that are turned "on" will print. Four columns will print, RAM;
ROM; 200 and 900 series tables; and EEPROM. Identifying headings print above each column.
Change Program Mode Password
Press (*,7,8, followed by a 5 digit number) to change the PASSWORD number for entering the
Summary of Contents for WEIGH SCALE BLENDER WSBMB Series
Page 17: ...M A G U I R E P R O D U C T S I N C 17 W E I G H S C A L E B L E N D E R...
Page 123: ...M A G U I R E P R O D U C T S I N C 123 W E I G H S C A L E B L E N D E R Technical Drawings...
Page 124: ...M A G U I R E P R O D U C T S I N C 124 W E I G H S C A L E B L E N D E R...
Page 125: ...M A G U I R E P R O D U C T S I N C 125 W E I G H S C A L E B L E N D E R...
Page 126: ...M A G U I R E P R O D U C T S I N C 126 W E I G H S C A L E B L E N D E R...
Page 127: ...M A G U I R E P R O D U C T S I N C 127 W E I G H S C A L E B L E N D E R...
Page 128: ...M A G U I R E P R O D U C T S I N C 128 W E I G H S C A L E B L E N D E R...
Page 129: ...M A G U I R E P R O D U C T S I N C 129 W E I G H S C A L E B L E N D E R...
Page 130: ...M A G U I R E P R O D U C T S I N C 130 W E I G H S C A L E B L E N D E R...
Page 131: ...M A G U I R E P R O D U C T S I N C 131 W E I G H S C A L E B L E N D E R...
Page 132: ...M A G U I R E P R O D U C T S I N C 132 W E I G H S C A L E B L E N D E R...
Page 133: ...M A G U I R E P R O D U C T S I N C 133 W E I G H S C A L E B L E N D E R...
Page 134: ...M A G U I R E P R O D U C T S I N C 134 W E I G H S C A L E B L E N D E R...
Page 143: ...M A G U I R E P R O D U C T S I N C 143 W E I G H S C A L E B L E N D E R...