Section 4. Commands
11
Table 4-1. SWA Command
BITS FUNCTION
7
6
5
4
3
2
1
0
0
0
0
Reserved
0
0
1
Baud Rate: 300
0
1
0
Baud Rate: 600
0
1
1
Baud Rate: 1200
1
0
0
Baud Rate 2400
1
0
1
Baud Rate: 4800
1
1
0
Baud Rate: 9600
1
1
1
Baud Rate: 19200
0
0
0
Data, Stop Bits, Parity: 8, 1, None
1
0
0
Data, Stop Bits, Parity: 8, 2, None
0
0
1
Data, Stop Bits, Parity: 8, 1, Even
1
0
1
Data, Stop Bits, Parity: 8, 1, Odd
0
1
0
Data, Stop Bits, Parity: 7, 1, Even
1
1
0
Data, Stop Bits, Parity: 7, 2, Even
0
1
1
Data, Stop Bits, Parity: 7, 1, Odd
1
1
1
Data, Stop Bits, Parity: 7, 2, Odd
0
CTS/DSR: Use
1
CTS/DSR: Ignore
0
Intercharacter
Delay:
No
1
Intercharacter
Delay:
Yes
SWA PARAMETERS
The SWA functions are listed in Table 4-1 and described below.
Baud Rate
The baud rate is one of seven speeds at which the MICR Plus communicates with the host. The
lowest speed is 300 baud, and the highest is 19200.
Data, Stop Bits, and Parity
Data refers to the number of data bits used to transmit every character; the options available are
7 or 8. Stop Bits refer to the number of bits used to indicate the end of transmission for every
character; the options available are 1 or 2. Parity refers to a means of detecting bit-level
transmission errors for every character; the options available are None, Even or Odd.
Summary of Contents for MICR Plus
Page 5: ...v ...
Page 8: ...Figure 1 1 MICR Plus viii ...
Page 14: ...MICR PLUS RS 232 6 ...
Page 30: ...MICR PLUS RS 232 22 ...
Page 48: ...MICR PLUS RS 232 40 ...
Page 60: ...MICR PLUS RS 232 52 ...
Page 64: ...MICR PLUS RS 232 56 ...
Page 68: ...MICR PLUS RS 232 60 ...
Page 70: ...MICR PLUS RS 232 62 ...