MagneSafe V5
46
ES JIS Type 2 Property
Property ID:
0x1D
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x7F ‘DEL’
Description:
This character is sent as the end sentinel for cards that are encoded in the JIS
type 2 format. If the value is in the range 0 – 127 then the equivalent ASCII
character will be sent.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.
Pre Card String Property (KB, BulleT, UART, RS-232)
Property ID:
0x1E
Property Type:
String
Length:
0 – 7 bytes
Get Property:
Yes
Set Property:
Yes
Default Value:
No string with a length of zero.
Description:
The value is an ASCII string that represents the reader’s pre card string. This
string can be 0 – 7 bytes long. This string is sent prior to all other card data.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.
Example Set
Pre Card String
property Request (Hex):
Cmd Num
Data Len
Prp ID
Prp Value
01
04
1E
31 32 33
Example Set
Pre Card String
property Response (Hex):
Result Code Data Len
Data
00
00
Example Get
Pre Card String
property Request (Hex):
Cmd Num
Data Len
Prp ID
00
01
1E
Example Get
Pre Card String
property Response (Hex):
Result Code Data Len
Prp Value
00
03
31 32 33