MT-95 RS-232 HiCo/LoCo Encoder/Reader
40
Select option to change
Esc=exit
I)dle Display E)ncode Energy
C)ard Time
6. Select
C
ard Time and the following will appear:
Type in Encode Timeout: [Ins] Enter=done
030 Seconds (Max=255, 0=Disable Timeout)
7. Specify the number of seconds that will be allowed before the encode operation is
automatically terminated. Press
Enter
when done.
8. Press
Esc.
9. Turn the power off.
10. Disconnect the keyboard.
11. Connect the communication cable.
12. Turn the power on.
MT-95 USER MESSAGES
Here is a full set of conditions and messages (where <Idle Top> and <Idle Bottom> are the user-
defined idle messages). Messages are centered in the line and other punctuation may be
included:
Idle (with or without a card):
<Idle
Top>
<Idle
Bottom>
Read command issued, no card:
<Idle
Top>
Insert card for reading
Read command issued and card in slot:
<Idle
Top>
Slide card right when ready
After read (for at least 1 second):
ISO format data read on track 1 2
Waiting for Host Response
After read (and host has responded, even if card still in slot):
<Idle
Top>
<Idle
Bottom>
Encode command issued, no card:
Encoding data on track 1 2
Insert card for encoding (Auto)
Encode command issued and card in slot:
Summary of Contents for 31010019
Page 7: ...vii ...
Page 8: ...viii Figure 1 1 MT 95 Encoder Reader ...
Page 12: ...MT 95 RS 232 HiCo LoCo Encoder Reader 4 Figure 1 2 Encoder Parts and Card Orientation ...
Page 22: ...MT 95 RS 232 HiCo LoCo Encoder Reader 14 ...
Page 34: ...MT 95 RS 232 HiCo LoCo Encoder Reader 26 ...
Page 44: ...MT 95 RS 232 HiCo LoCo Encoder Reader 36 ...
Page 50: ...MT 95 RS 232 HiCo LoCo Encoder Reader 42 ...