Magpowr PA-20 Installation Manual Download Page 1

 

 

222 W. Memorial Road, Oklahoma City, OK  73126-0508 

 Phone: 

1-800-624-7697 

 Fax: 405-755-8425 

 www.magpowr.com 

 E-mail: [email protected] 

 

 

INSTALLATION MANUAL

 

PA-90

 

Power Amplifier

 

 

 

All of the information herein is the exclusive proprietary property of Maxcess International, and is disclosed with the 

understanding that it will be retained in confidence and will neither be duplicated nor copied in whole or in part nor 

be used for any purpose other than for which disclosed. 

 
Copyright 2004, all rights reserved.  
 
Periodically there will be updates to this manual.  The latest version is available at 

www.magpowr.com

 or by calling 

1-800-MAGPOWR (624-7697). 
 
 

INTRODUCTION

 

 

The MAGPOWR

®

 Model PA-90 power amplifier is intended for use with the DIGITRAC

®

 2, VERSATEC™ or  

EZ-TRAC

®

 for the control of electromagnetic clutches and brakes. 

 

 

PA-90 INSTALLATION 

 

The PA-90 power amplifier is to be installed inside the control.  Set jumpers on JP1 for current range before 

installation.  Wiring to and from the control and power amp must be done with double or reinforced insulation or 

protective screening which provides protective separation.  All wiring outside the control enclosures should comply 

with the essential requirements of the appropriate standard(s) and is the responsibility of the installer. 

 

   WARNING: DISCONNECT MAINS BEFORE OPENING ENCLOSURE 

 

 

MAINTENANCE

  

 

The only maintenance that may be required on the PA-90 is fuse replacement.  Replacement of any fuse requires 

opening the enclosure, which circumvents the enclosure IP rating.  To change a fuse: 

 

On a PA-90 power amplifier mounted in the D2,   

 

On a PA-90 power amplifier mounted in the D2E, 

D2SLVMD, VTC, EZ or their variants: 

 

 

 

VTCE, EZE or its variants: 

 

1.  Disconnect the supply mains. 

 

 

 

1.  Disconnect the supply mains. 

2.  Remove the two screws which retain the top cover.  

2.  Open the door by loosening the two 

3.  Remove the top cover. 

 

 

 

 

       retaining screws. 

4.  Remove and replace the blown fuse.  

 

 

3.  Remove and replace blown fuse on the PA-90 

5.  Re-install the top cover.    

 

 

 

4.  Close the door and retighten the 

6.  Reconnect supply mains.    

 

 

 

      retaining screws. 

  

        5. 

 

Reconnect 

supply 

mains. 

 

 

 

 

 

 

 

 

 

850A234-1 

10/04 Rev. B 

Reviews: