PARAMETERS
www.maxcessintl.com
DLCA NET-ECAT
MI 850A365 1
Page 36 of 72
7.2
Alarm setup and operation
The following parameters describe the setup and operation of the alarms.
Parameter Description
Units Default Range
AL1.1
AL2.1
Tension Channel/Zone used for alarm
DLCA NET 1-ECAT
0 = Channel 1
1 = Channel 2
2 = Tension Sum
DLCA NET 2-ECAT
0 = Tension Zone 1
1 = Tension Zone 2
0
DLCA NET 1-ECAT
{0, 2}
DLCA NET 2-ECAT
{0, 1}
AL1.2
AL2.2
Alarm activation type.
0
{0, 3}
0 =
1 =
2 =
3 =
Alarm ON when tension is above the
alarm high compare value.
Alarm ON when tension is below the
alarm low compare value.
Alarm ON when tension is either above
the alarm high compare value or below
the alarm low compare value.
Alarm ON when tension is below the
alarm high compare value and above
the alarm low compare value.
AL1.3
AL2.3
Alarm high compare value
1
500
{0, 999000}
AL1.4
AL2.4
Alarm low compare value
1
0
{0, 999000}
AL1.5
AL2.5
Alarm hysteresis percent. Hysteresis percent
is a percentage of maximum tension.
0.01%
0
{0, 9999}
AL1.6
AL2.6
Alarm ON delay time. (The alarm ON output
is delay by this number of seconds.)
0.01
s
0
{0, 9999}
AL1.7
AL2.7
Alarm OFF delay time. (The alarm OFF output
is delay by this number of seconds.)
0.01
s
0
{0, 9999}