OPERATION
www.maxcessintl.com
DLCA NET-ECAT
MI 850A365 1
Page 24 of 72
4.5
LED indicators
Power Good (Yellow)
The Power Good status indicator shows power good or a fault. If power
is good and no faults then the power good LED is ON. If there is a fault
detected then the power LED is flashing. One flash per second indicates
a load cell check error. Two flashes per second indicates there is a
voltage error on either the load cell excitation, internal 12V or internal
5V supplies. The load cell check only runs during power-up. The
voltage monitoring check runs continuously.
Tension display (Green)
The LEDs indicate which channel or sum is being displayed.
While displaying tension, press [Enter] to cycle the display through the
channels.
-
For one tension zone, the display cycles through Channel 1,
Channel 2, and Tension Sum.
-
For two tension zones, the display switches between Channels 1
and 2 (Tension Zones 1 and 2, respectively).
Alarms (Red)
There are two alarm indicators showing whether each alarm is active or
not.
EtherCAT Error (Red)
This indicator shows the EtherCAT error status.
EtherCAT Run (Green)
This indicator shows the EtherCAT run status.
EtherCAT RUN
Channel 1 (Tension Zone 1)
Channel 2 (Tension Zone 2)
Tension Sum
Alarm 1
Alarm 2
EtherCAT ERROR
1 -
2 -
Power good and fault LED
EtherCAT link / activity LED
Figure 9. LED indicators