Magnum MN-101 Quick Reference Manual Download Page 1

Quick Reference Guide 

V2.12 

Relates To Firmware Version 01.07.xx

 

MN-101 

 

 

 

Chrosziel GmbH, Klausnerring 6, 85551 Heimstetten, Germany, Phone +49 89 901 091 0, Fax +49 89 447 0861,

 

[email protected]

http://www.chrosziel.de

 

 

 

 

Motor Control Unit  

Hand Control Unit 

 

 

 

 
 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

Light socket  

Only  for  original  scale 
illumination LED light! 

 

Battery 

7.2V SONY FM-50/55 

Type 

Power Button (On/Off) & LED 

Green = Battery Good 
Flashing  =  Battery  Low  -  change  battery 
Unit  switches  off  automatically,  when 
battery power becomes too low

 

 

 

Area of built-in GHz Antenna 

Do not cover- keep clear! 
 

Camera  Record 
Start/Stop 

LED flashes  = Record is on

 

 

Automatic adjustment of lens-scale 
limits  and  motor-test  of  connected 
digital motor: 

 

This  adjustment  has  to  be  made  whenever 
motor and/or lens are changed. 
Do not block or stop the lens while end stops 
are  checked,  all  parameters  will  then  be 
stored incorrectly! 

 

Procedure:

 

• engage motor onto lens (not at an     
   end stop) 
• Push "Motor Cal." button, red LEDs flash 
• Motor starts turning slowly 
 
The  lens-scale  limit  will  be  checked  and 
stored automatically.

 

 

 

Motor Socket 

 
Type: Lemo EGG. 1B. 307 
 
Pin 1: Motor 

– 

Pin 2: Motor + 
Pin 3: Encoder channel A 
Pin 4: +5V 
Pin 5: earth/ground 
Pin 6: Encoder channel B 
Pin 7: Sense 

 

 

Power LED 

Green = Power Good (>12V) 
Red = Input voltage low 
Flashing = voltage drop occurred 

 

Power  In  (10V  -30V;  with 
electronic  Fuse  &  reverse 
protection) & Cam Start/Stop 

 
Type: Lemo 0B.305 
Pin 1:  Battery plus  
Pin 2:  CAM Relay contact 1 
Pin 3:  CAM Relay contact 2 
Pin 4:  Battery minus / GND 

Hand wheel with fixed Fluid 
Drag 

Accepts 2 different types of scales: 
      Big Ring  
      Small Ring (as shown in photo) 
 

 

 

 

Menu Navigation 

Press  Center  button  to 
enter the Setup Menu

 

 

Battery Release 

Slide to the right to change battery 

USB Socket for Software Updates and USB Status LED 

(always update both MCU and hand unit)

 

Software updates are provided by Chrosziel, when available . 
Update Procedure: 

  Copy  the  two  software  files  into  the  root  of  an  USB  stick  (FAT/FAT32 

formatted) 

  Plug USB stick into socket. 

  Power down the unit 

  Press and hold 

down “Motor Cal” button and repower the receiver. 

  Unit  will  perform  the  update  indicating  the  progress  by  different  LED  blinking 

patterns on the front. After update the Unit restarts automatically  

USB  Socket  for  Software 
Updates 

(always  update  both  MCU 

and hand unit)

 

 

Software  updates  are  provided  by 
Chrosziel, when available. 
 
Update Procedure: 

  Copy  the  two  provided  software 

files  into  the  root of  an  USB  stick 
(FAT/FAT32 formatted) 

  Power down the handset  

  Plug USB stick into socket. 

  Press 

and  hold  down  “REC” 

button and power on the handset. 

  Unit  will  perform  the  update 

indicating 

the 

progress 

by 

different  LED flashing  patterns  on 
the  front.  After  update  the  unit 
restarts automatically  

Area of Built-in GHz Antenna 

Do not cover- keep clear! 

Cam  Start/Stop  indicator 
LED 

blue 

relay 

switches 

active/connected  
off 

relay 

switches 

inactive/disconnected 

 

Radio Channel Se Rf Error LED 

 

Select  radio  channel  within  the  2.4  GHz  Band 
(select  5  ..  F).  Red  LED  goes  on  if  connection 
error  occurs.  Channels  0..4  not  valid!  If  chosen, 
LED is flashing.  

 

Cam Start/Stop 

 
Type: Lemo ECB.0B.309 
Pin 8: CAM Relay 1 
Pin 9: CAM Relay 2 

 

Rf Error LED 

 

Rf  Error  LED  goes  on  if  no 
connection  to  at  least  one 
hand 

unit 

could 

be 

established. 
Choose same channel in the 
Set  Up  menu  of  the  hand 
unit.

 

 

 

Motor Status Red LEDs 

 
Signaling 

Slow  blinking    =

  motor  limits 

need to be calibrated 

Fast 

flashing 

=

 

motor 

calibration in progress 

Off  with  motor  connected  =

 

motor  limits  are  calibrated, 
ready to shoot 

4  User  assignable  Keys 
(U1 .. U4) 

Currently  fixed  to  spread  the 
wheel scale 

6x 1/4" Threads  

for attaching of  additional 
accessories. 

Caution:  
Maximum length of screw 
turned into the thread is 
<=  8 mm (5/16")! 

 

 

 

Reviews: