Part Number 64-0015
Page 1 of 2
Magnum Energy Inc.
1111 80th Street SW, Suite 250
Everett, WA, USA 98203
www.magnumenergy.com
Supplement to ME and MS Series Operator’s Manual
Notes on Changes
This supplement provides information on the ME2000 and MS2000. The ME2000 is a new model of the ME
Series family and has been specifically developed to meet the operational requirements of OEM applications.
The ME2000 includes two versions, the ME2000 and ME2000-20B which includes two 20 amp output breakers.
The MS2000 is a new model of the MS Series family and is designed to add variety to the pure-sine wave
product line. Both the ME2000 and MS2000 models should be installed as described in the operators’
manuals except for the AC wiring which is described below.
AC Installation
The ME2000 (-20B) and MS2000 models use wire leads to connect to the system’s AC wiring. View the
following figures to correctly install your unit.
Warning: Prior to the installation, read the ME Series or MS Series Operator’s Manual depending on
your inverter model and pay particular attention to all safety information. Installing these units
without being aware of all safety precautions may cause harm to personnel and/or equipment.
ME2000 / MS2000 AC Wiring
30
AC
Main
Panel
AC IN
(30A breaker)
AC OUT
AC HOT IN
BLACK
WHITE
GREEN
WHITE w/BLACK
AC NEU IN
AC GROUND
AC GROUND
AC
Outlets
AC HOT IN
BLACK
WHITE
GREEN
WHITE w/BLACK
AC NEU IN
AC GROUND
AC GROUND
AC
Sub-
Panel
AC NEU OUT
BLUE
AC HOT 1 OUT
AC NEU OUT
BLUE
AC HOT 1 OUT
CB2
OUTPUT 2
CB3
INPUT 30 A
Engineered and Manufactured in the U.S.A.
Serial Number
Model: MS2000 Inverter/Charger
Inverter Operation:
Continuous output power: 2000 Watts @ 25
°C
Peak output current 29.0AAC, 10 sec surge (unregulated)
Output provided with integral protection against overload
DC Input: 10.0-15.5VDC
Continuous input current: 225A @ 12.6VDC
Charger Operation:
Continuous Charger current: 100ADC @ 11-14VDC
AC Input: 120VAC/60Hz @ 30 Amps Max
(Charger can use up to 16 amps of 120VAC)
Power Factor: @ 10% to 100% charge > .95
Magnum Energy Inc.
1111 80th St S.W. Suite 250
Everett, WA 98203
T1-00001
Date Code -
AC current distortion at rated power <5% THD
Q
tr 1 2 3 4 Y
ear 06 07 08 09 10
CB1
OUTPUT 1
Figure 1, AC Wiring for the ME2000 and MS2000