OPERATING AND MAINTENANCE MANUAL

Summary of Contents for MagniSmartech

Page 1: ...OPERATING AND MAINTENANCE MANUAL...

Page 2: ...bed frame motor control anti snoring functions a vital signs acquisition system and chromotherapy MagniSmartech Mattress version with vital signs acquisition system and chromotherapy MagniSmartech Mo...

Page 3: ...ital signs acquisition system and chromotherapy MagniSmartech Mattress with vital signs acquisition system and chromotherapy MagniSmartech Motor with a motorized slatted bed frame motor control anti s...

Page 4: ...sed carefully read the technical instructions contained in this manual and carefully follow them Keep this manual and all its attachments in a place that is accessible and known to the user This opera...

Page 5: ...th the product Alessanderx S p A Address Via San Leonardo da Porto Maurizio 24 26 28 59100 Prato PO ITALY Phone 39 0574 51011 Fax 39 0574 5101235 Version Serial number Date of manufacture Input voltag...

Page 6: ...ence to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own ex...

Page 7: ...ransmitter This device complies with the following requirements FCC Federal Communications Commission Part 15 ISED Industry Canada RSS 102 and RSS 247 and RSS Gen Operation is subject to the following...

Page 8: ...rticipated in the training course organized by Alessanderx S p A when installing the product and who have fully read and understand the instructions contained in this manual Users are required to full...

Page 9: ...electrical parts The user must avoid unsafe operations on the product that could compromise its balance It is strictly prohibited to remove or disengage the safety devices 1 4 CONNECTIONS The main ele...

Page 10: ...rtech system drive motors All the electrical connections in the distribution system of the MagniSmartech Motor and MagniSmartech are provided in compliance with the harmonized and technical standards...

Page 11: ...main power supply fails the chromotherapy system will not operate NOISE The product was designed and developed to reduce the sound power level at the source and show the noise level within the limits...

Page 12: ...n of the use of certain hazardous substances in electrical and electronic equipment Decision of the Commission 2000 532 CE and subsequent amendments and integrations that supersedes decision 94 3 CE w...

Page 13: ...ate operation put the product out of service by disconnecting the power supply cable s The power supply cable s must be set so that it is not dragged away walked on or damaged by moving parts during i...

Page 14: ...vehicle the battery may experience damage or even catch fire NEVER USE a different power supplier than the supplied one The use of different or non compatible transformers may cause fires injuries to...

Page 15: ...re performed prior to installation in compliance with the modalities reported hereinunder 1 check the components to be assembled ascertain the presence and integrity of all the material that the produ...

Page 16: ...the MagniSmartech Station to the MagniSmartech Mattress through the ethernet data cable 2 Connect the MagniSmartech Mattress to the LEFT and RIGHT LED cables 3 Connettere alla MagniSmartech Station il...

Page 17: ...systems 2 Connect the MagniSmartech Motor to the LEFT and RIGHT ethernet remote cables 3 Connect the two push button boards to the two ethernet remote cables The position has no influence 4 Connect t...

Page 18: ...redentials For further details consult the following website www magnismartech com 7 If the user connects the MagniSmartech Mattress system to their own wifi network the B button s reference status LE...

Page 19: ...rvene In both cases the orange LED light on the button s board will light up to confirm that the anti snoring system is operational 9 Once triggered the anti snoring system will take the bedframe back...

Page 20: ...ed bedframe The MagniSmartech Mattress version collects vital parameters breathing and heartbeat during the rest stage which are determined through a set of sensors connected to a central control card...

Page 21: ...e user Massage system on Incline of the motorized slatted bed frame in the front area head and shoulders for MagniSmartech Motor and MagniSmartech versions Detection of the optimal position for the mi...

Page 22: ...able RJ45 to allow adjusting by handling through electrical drive motors the incline of the head shoulders Head up down and legs Feet up down of the user Furthermore controls are available to start th...

Page 23: ...n he she will activate the function to stop the recording The cell phone does not need to be beside the bed while sleeping The different records individual session and statistics can be displayed thro...

Page 24: ...y with the time intervals indicated for the maintenance interventions To ensure the perfect operation of the product make sure that any replacement if needed is exclusively performed with Alessanderx...

Page 25: ...y the manufacturer s Specialized personnel only at the specific request of the user 4 3 2 Routine electrical maintenance Before carrying out maintenance or a replacement of electrical or electronic eq...

Page 26: ...p but the anti snoring system does not work Improperly connected microphone Microphone positioned incorrectly The connecting plug is not inserted properly Control pad functions locked Replace the cont...

Page 27: ...the relevant user s and maintenance manual The hydraulic units if any mainly consist of metal and plastic Before disposing comply with the Manufacturer s indications as related to the recovery of the...

Page 28: ......

Page 29: ...MANUEL D UTILISATION ET DE MAINTENANCE...

Page 30: ...otoris e et anti ronflement et syst me d acquisition des param tres vitaux et de chromatoth rapie Version MagniSmartech Mattress avec syst me d acquisition des param tres vitaux et de chromatoth rapie...

Page 31: ...res vitaux et de chromatoth rapie MagniSmartech Mattress avec syst me d acquisition des param tres vitaux et de chromatoth rapie MagniSmartech Motor avec sommier lattes motoris et fonction de contr le...

Page 32: ...marche les systemes MagniSmartech dans la version achetee lire attentivement les instructions techniques contenues dans cette publication et suivre attentivement les indications donnees Conserver le p...

Page 33: ...duit Alessanderx S p A Adresse Via San Leonardo da Porto Maurizio 24 26 28 59100 Prato PO ITALIE T l 39 0574 51011 Fax 39 0574 5101235 Version Num ro de s rie Date de production Tension d entr e AC 24...

Page 34: ...cet appareil dans une zone r sidentielle est susceptible d entra ner des interf rences pr judiciables auquel cas l utilisateur devra supprimer ces interf rences ses frais Si cet quipement produit des...

Page 35: ...ou tout autre transmetteur Cet appareil est conforme avec les xigences suivantes FCC Federal Communications Commission Partie 15 ISED Industry Canada RSS 102 and RSS 247 and RSS Gen L operatjon est s...

Page 36: ...e l installation du produit et qui ont int gralement lu et compris les instructions contenues dans ce manuel Il faut respecter int gralement les instructions les avertissements et les r gles g n rales...

Page 37: ...s parties lectriques L utilisateur doit viter les op rations peu s res sur le produit qui pourraient compromettre son propre quilibre Il est strictement interdit d enlever ou de neutraliser des dispos...

Page 38: ...ctriques d actionnement du syst me MagniSmartech Tous les raccordements lectriques de l installation de distribution dont sont munies les versions MagniSmartech Motor et MagniSmartech ont t ex cut s e...

Page 39: ...de chromatoth rapie ne fonctionnera pas BRUIT Le produit con u et r alis de fa on r duire la source au niveau de la puissance sonore pr sente les niveaux de bruit dans les limites des normes en vigue...

Page 40: ...Commission 2000 532 CE e s m i qui remplace la d cision 94 3 CE qui institue une liste de d chets conform ment l article 1 point a de la directive 75 442 CEE du Conseil relative aux d chets et la d ci...

Page 41: ...es c ble s d alimentation doit doivent tre pos s de telle fa on que pendant le fonctionnement il ne soit pas entra n pi tin ou endommag par les parties mobiles Contr ler le c ble d alimentation en v r...

Page 42: ...rie pourrait s ab mer ou m me prendre feu N UTILISEZ JAMAIS une alimentation diff rente de celle qui a t fournie L usage de transformateurs diff rents ou non compatibles peut provoquer des incendies c...

Page 43: ...op rations de contr le avant l installation se font selon les modalit s rapport es ci dessous 1 contr le des composants assembler v rifier la pr sence et l int grit de tout le mat riel composant le pr...

Page 44: ...romatoth rapie 1 Raccorder avec le c ble de donn es Ethernet de la MagniSmartech Station au MagniSmartech Mattress 2 Raccorder au c ble LED MagniSmartech Mattress le c ble LED gauche et le c ble LED d...

Page 45: ...nce d Ethernet gauche et le c ble d Ethernet distance droite au MagniSmartech Motor 3 Raccorder les deux t l commandes aux deux c bles Ethernet distance La position n a pas d importance 4 Raccorder le...

Page 46: ...ateur enregistr Pour plus de d tails consulter le site www magnismartech com 7 Si l utilisateur connecte le syst me MagniSmartech Mattress son propre r seau wifi le LED de statut de r f rence au bouto...

Page 47: ...de pour confirmer que le syst me anti ronflement est en fonction 9 Le syst me anti ronflement une fois lanc remettra le sommier en position de d part apr s 60 secondes 3 DESCRIPTION DU FONCTIONNEMENT...

Page 48: ...on MagniSmartech Mattress est un syst me servant r cup rer les param tres vitaux respiration et battement cardiaque pendant la phase de repos pourvu d un ensemble de capteurs raccord s sur une fiche d...

Page 49: ...on allume Inclinaison du sommier a lattes motorise zone anterieure tete et epaules pour les versions MagniSmartech Motor et MagniSmartech La determination de la meilleure position du micro par rapport...

Page 50: ...ur permettre de r gler moyennant un mouvement l aide de moteurs actionn s lectriquement l inclinaison de t te paules T te en haut en bas et jambes Pieds en haut en bas de l utilisateur En outre il y a...

Page 51: ...donnera le signal d arr t de l enregistrement Il n est pas n cessaire de tenir son cellulaire positionn c t du lit pour la p riode de couchage Les divers enregistrements session unique et statistique...

Page 52: ...tent Respecter les p riodicit s indiqu es pour les interventions de maintenance Pour garantir un parfait fonctionnement du produit il est n cessaire que les remplacements ventuels soient effectu s ex...

Page 53: ...rvention de maintenance doit tre r alis e par le Personnel sp cialis mis disposition par le constructeur sur demande sp cifique de l utilisateur 4 3 2 Maintenance lectrique p riodique Avant de r alise...

Page 54: ...Micro pas bien raccord Micro mal positionn Prise de raccordement pas bien ins r e Fonctions bloqu es sur la t l commande Changerlat l commande Contr lerlesraccordements Demanderl interventiondemainten...

Page 55: ...usage et la maintenance Les groupes hydrauliques ventuellement pr sents sont compos s surtout de m tal et de plastique Avant l coulement respecter les indications du constructeur en ce qui concerne l...

Page 56: ...ALESSANDERX S P A Via San Leonardo da Porto Maurizio 24 26 28 59100 Prato Italia Tel 39 0574 51011 Fax 39 0574 5101 235 info magniflex com www magniflex com G 01 19 N 01 18...