Generator failure emergency procedure:
1. Lift the battery backup guard
2. Battery backup switch.................ON
3. Not essential electrical utilities....OFF
4. Land at the closest airport, monitoring tension values of the implants. In case of tension
value in the red sector, prepare for an emergency landing
5. After landing, call for assistance at the authorized centres.
6. Stop flying
4.8.4 LINE A AND/OR LINE B LED BLINKING
In case of an anomaly due to an uncertain connection, one parameter or one engine
management sensor, the failure is indicated by the flashing of the WARNING LED “Line A” and/
or “Line B”. The pilot has to proceed as follows.
A. Red LED 1 “Line A” flashing:
1. Trim the gyroplane at safe altitude and speed (if flying)
2. Line A switch...............................OFF
3. Line A switch...............................ON
If after 5 seconds the LED is still flashing:
4. Continue flying till the destination
5. Once landed, contact the assistance service
If after 5 seconds the LED is OFF:
4. Continue flying
5. Once landed, log the anomaly on the logbook
B. Red LED 2 “Line B” flashing:
1. Trim the gyroplane at safe altitude and speed (if flying)
2. Line B switch ..............................OFF
3. Line B switch ..............................ON
If after 5 seconds the LED is still flashing:
4. Continue flying till the destination
5. Once landed, contact the assistance service