magnetic
Demineralization
Refill station (NF plus)
Instructions for use
...einfach besser
Page 1: ...magnetic Demineralization Refill station NF plus Instructions for use magnetic einfach besser ...
Page 2: ...7 Untermünkheim Tel 49 7944 94199 0 Fax 49 7944 94199 19 info magnetic online de www magnetic online de Managing Shareholder Michael Bader VAT ID No DE 255 018 730 Commercial Register No HRA 571362 Register Court Stuttgart Version NF_ENG_08 2020 ...
Page 3: ...Refill station NF plus Contents The function 4 Use with heating system filling hose 4 Permanent connection 5 Operating the meausuring computer 6 Replacing the mixed bed resin 7 Calculating the capacity 8 Troubleshooting 9 Technical data 10 Maintenance 11 ...
Page 4: ...he function The magnetic NF plus removes limescale and aggressive water constituents like sulphates nitrates and chlorides from the filling water The device works on the basis of a mixed bed resin ion exchanger and delivers demineralised water quality for every heating system size This method does not add any chemicals to the water The device works without external electrici ty connection Use with...
Page 5: ...in front of the filling station if the place of installation is subject to DIN EN 1717 Germany NF 2 plus 6 plus NF 12 plus NF 25 plus Untreated water backflow preventer Keep taps valves closed when not in use Untreated water Untreated water backflow preventer backflow preventer Keep taps valves closed when not in use Keep taps valves closed when not in use The regulations of the water supply utili...
Page 6: ...tomatic monitoring of the conductivity Set limit Press the S key to set the limit value for the conductivity in the display The increase step is 15 μs cm A longer pressing of the S key resets the value back to zero Switch to automatic mode after you have set a limit value Do that by pressing the A key to first do a manual test Then press the A key again to switch to the automatic mode Auto will th...
Page 7: ...ied water permeable collec tion bag 3 Connect the inlet to a drinking water tap with a hose 4 Open the inlet tap and the drain tap and flush out the resin until clear water comes out the resin is then completly emptied 5 Close the inlet tap and open the vent tap on the lid Air can now get into the device and water in the filling station can flow out of the drain tap 6 Used mixed bed resin can be d...
Page 8: ...tation removes all minerals 0 500 1000 1500 2000 2500 3000 1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 CAPACITY IN LITER TOTAL HARDNESS IN DH CAPACITY REFILL STATION NF plus NF 2 plus NF 6 plus Capacity of the mixed bed resin 0 1000 2000 3000 4000 5000 6000 7000 8000 1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 CAPCITY IN LITER TOTAL HARDNESS IN DH CAPACITY REFILL STATION NF plus NF 12 plus NF 25 plus Refi...
Page 9: ...ng the batteries Remove the four front screws of the housing see illustration below and insert three batteries AAA alkaline into the battery holder The front part of the housing can be turned by 90 or 180 if desired before fastening with the screws Video The resin is exhausted quicker than calculated Loss of capacity There is probably no fault It could be that the untreated water contains not only...
Page 10: ...ter for flow rate total water flow quantity water quality and limit value checking Battery powered with automatic switch on function Suitable for permanent connection if the specific requirements and plan ning directives e g DIN EN 1717 are complied with Refill station NF 2 plus NF 6 plus NF 12 plus NF 25 plus Annual consumption 250 l 500 l 2500 l 10000 l Capacity at 1 dH 4 5 m3 10 m3 24 m3 48 m3 ...
Page 11: ...magnetic einfach besser 11 Date Resin changed Liter total Signature Maintenance Installer Object Date of installation Serial number ...
Page 12: ...G Am Richtbach 5 D 74547 Untermünkheim Tel 49 7944 94199 0 Fax 49 7944 94199 19 info magnetic online de www magnetic online de Managing Shareholder Michael Bader VAT ID No DE 255 018 730 Commercial Register No HRA 571362 Register Court Stuttgart ...