30
Control unit MGC
Description "mSwing Connect" programme
4.6
"Safety settings" tab
WARNING
Entering values that do not fit the blocking element!
Entering values that do not fit the installed blocking element can
lead to increased speed and incorrect torque, and thus to
injuries.
›
Only MHTM™ FlowMotion® service experts may enter the
values for safe operation.
›
The entered values must fit the installed blocking element.
Use the "Safety" tab to enter the parameters for safe operation in low-energy
mode according to DIN EN 17352 for the swing door.
The values to be entered depend on the installed blocking element.
4.6.1
Activating "Safety" tab and entering safety parameters
Prerequisite
›
The latest version of the "mSwing Connect" programme is installed on the
laptop.
›
The latest software is installed on the control unit MGC.
Activating "Safety" tab
The "Safety" tab is not displayed by default.
1. Click on the "Safety configuration" button in the header.
√
The dialog box for entering the password is opened.
2. Enter "Service Password".
√
The "Safety" tab is displayed.