15
Control unit MGC
Parameterising mSwing
3
Parameterising mSwing
The swing door is parameterised at the factory for applications with an
opening angle of 2 x 90°.
You have the following possibilities to parameterise the control unit MGC:
›
Directly at the control unit MGC
›
Via the "mSwing Connect" programme.
The "mSwing Connect" programme also allows you to test the function of the
swing door.
3.1
Parameterisation directly at the control unit
The control unit is only accessible when the blocking element, the hood and
the outer tube have been removed.
1
2
M
ag0094
7
Fig. 1:
Position control unit in the mSwing
1 Control unit MGC
2 Control unit operating keys (4 pieces)
IMPORTANT!
For access to the control unit, see separate operating instructions
"Swing door mSwing MHTM™ FlowMotion® (Doc.ID:
5817,0032)".