53
Control unit MGCplus
Description of menus and parameters
6.2.6.2
GED no. 1 / GED no. 2
The GEDs are parameterised using the "Mode", "Mode wrong direction" and
"Validation response" parameters.
For certain events such as "On tailgating" etc. you can choose between differ-
ent display patterns. Display pattern descriptions:
Operational view > Main menu > Settings > Signalling > GED no. 1 / GED no. 2
Parameter
Description
Mode
Select the behaviour of the optional GED.
Options
›
Always off: The GED is dark.
›
Always red: The GED is permanently red.
›
Always green: The GED is permanently green.
›
Standby off: The GED is off when no validations are pending and no free
passage in that direction is possible. As soon as a validation is pending or
the direction is permanently free, the GED turns green.
›
Standby red: The GED is red when no validations are pending and no free
passage in that direction is possible. As soon as a validation is pending or
the direction is permanently free, the GED turns green.
›
Standby green: The GED is green when no validations are pending and no
free passage in that direction is possible. Validations can be accepted at
any time.
Factory setting
›
Standby green
Mode wrong direc-
tion
Select GED behaviour when a validated person tries passing the passage in
the wrong direction.
If no person tries to pass the passage in the wrong direction, the GED will
behave in accordance with the "Mode" parameter.
Prerequisite
This parameter is only effective if you have selected the "Standby off",
"Standby red" or "Standby green" option for the "Mode" parameter.
Options
›
Standard: The GED behaves in accordance with the setting for the "Mode"
parameter.
›
Off: The GED is dark when a validated person tries passing the passage in
the wrong direction.
›
Red: The GED display a red cross when a validated person tries passing
the passage in the wrong direction.
Factory setting
›
Red