The chapters 3.4.2 and 3.4.3 show the resulting operating mode and the result-
ing control unit behaviour depending on the input functions "Control direc-
tion 1" and "Control direction 2". Please also note the parameter descriptions
"Control variant" and "Delay permanent open".
The following symbols and abbreviations are used in the tables:
Symbol
Description
Set
Not set
–
Not relevant
OM (Open
mode)
The abbreviation OM indicates the open mode variant of the oper-
ating mode. In the open mode variants, the wings always remain
open. The wings are only closed in the event of an unauthorised ac-
cess attempt.