78
MPT-333
Spare parts and repair
1. Disconnect the pedestrian gate from the power supply. Ensure that the
system is powered down. Secure against reactivation.
DANGER
Danger to life, electrical voltage!
2. Loosen the connection line of the proximity sensor at the terminals.
3. Disassemble the proximity sensor. Loosen the nut for this purpose.
4. Mount new proximity sensor. Make sure that the distance to the cam is
between 0.5 and 2.0 mm.
5. Fasten the proximity switch. Tighten the nut.
6. Connect the connection line of the proximity sensor at the terminals.
7. Switch on power supply.
8. Check if the end position is recognised. If the end position is not detected,
check the distance to the switching cams.
0.2 – 2.
0
0.2 – 2.
0
Mag009
07
Fig. 36: Distance proximity sensor - switching cam