70
MPT-333
Electrical connection
Assembly
You may mount the access-control devices in the following positions, for exam-
ple:
›
Optional mounting pillar:
ä
›
Mounting bracket on the cage half:
ä
Optionally you may order the attachment set AMWMPT for the mounting
brackets by Magnetic.
Electrical connection
The access-control devices are connected to the control unit MGC.
ä
Separate electrical circuit diagram and document "Description of MGC con-
trol unit for MPT-333 Full Height Turnstile (Doc.ID: 5817,0027)".
8.7
Checking the electrical connections
After the electrical installation, check the following points:
›
Does the power supply match the specification on the type plate?
›
Are the prescribed protective devices installed?
›
Is the pedestrian gate connected according to electrical circuit diagram?
›
Is the emergency signal transmitter correctly connected?
›
Are the customer's signal transmitters and receivers correctly connected?
›
Are all screws firmly tightened?
›
Is the support beam earthed?
ä
›
Is the protective ground for the cover connected?
›
Is the protective ground for the service door connected?
›
Is the cover assembled correctly?
›
Is the service door closed?