MPT-333
Electrical connection
8.4
Connecting the mains cable
DANGER
Mortal danger by electric shock!
If the mains cable is not connected to the terminal clamps cor-
rectly, loosens from the connection clamps and touches the
housing or cover, there is a direct danger to life from electric
shock.
›
Only electricians must carry out work on the electrical system.
›
Connect mains cable according to the following description.
›
Install electrical protective devices.
ä
IMPORTANT!
The wire cross-section of the mains cable must be between 1.5
and 4 mm². Observe national provisions on line length and asso-
ciated line cross-section.
1. Disconnect the pedestrian gate from the power supply. Ensure that the
system is powered down. Secure against reactivation.
DANGER
Danger to life, electrical voltage!
2. Strip mains cable and strands according to the following figure.
20
8
30
8
2
3
1
Mag0081
0
Fig. 32: Stripping (dimensions in mm)
1 Phase
2 Zero conductor
3 Protective earth conductor