13.5 Closing or opening the barrier arm in case of power failure
In case of power failure, the barrier arm may be in the lower or
upper dead point. I.e. the barrier arm can no longer be easily
moved manually. In this case, proceed as follows:
1. Remove the barrier housing hood.
2. Remove the barrier housing door.
3. Press a tool straight into the lower tool bore. The lever arm is
pressed from the dead point
Upper tool bore for opening the barrier.
Lower tool bore for closing the barrier.
4. Mount the door if applicable.
5. Attach and lock the hood if applicable.
Mag00209
1
2
Fig. 54: Top and bottom tool bore
1
Upper tool bore for opening the barrier.
2
Lower tool bore for closing the barrier.