![Magnetic Autocontrol MHTM MicroDrive Access Series Operating Instructions Manual Download Page 38](http://html1.mh-extra.com/html/magnetic-autocontrol/mhtm-microdrive-access-series/mhtm-microdrive-access-series_operating-instructions-manual_3583810038.webp)
Barrier MHTM
TM
MicroDrive Access and Parking
Technical data
38
5815,5013US / Version 05
4.5
Plug-in module "Detector A–B"
Designation
Unit
Plug-in module "Detector A–B"
Current consumption
mA
50
Number of loop detectors
─
2 (A and B)
Inductance range
µ
H
70 to 500
Number of induction loop
sensitivity levels
─
10 levels
Response sensitivity
induction loop
%
Selectable: 0.01 to 2.0
Table 15: Plug-in module "Detector A–B"
4.6
Plug-in module "Radio"
Designation
Unit
Plug-in module "Radio"
Current consumption
mA
20
Frequency hand transmitter
MHz
433
HF-Modulation
–
FM/AM (depending on region)
Grant of equipment
authorization (Certificate)
–
FCC Identifier: QV2-SMD-53200RX
FCC 02-157
→
Table 16: Plug-in module "Radio"