Magneti Marelli Smart Gas Operating Manual Download Page 11

                                               

                                        

 

 
 

1161306-0 

32

4.2.3  HC test 

It  checks  the  presence  of  hydrocarbons  inside  the  gas  sampling  probe. 
Warning:  do  not  insert  the  gas  sampling  probe  in  the  vehicle  exhaust  pipe 
during this test. 

 

4.2.4  Leak test 

It checks the analyzer pneumatic seal by creating a vacuum in the pneumatic 
circuit. 
To  carry  out  the  test  in  automatic  mode,  the  user  shall  close  the  sampling 
probe and wait for a few seconds.  
Should  the  test  result  be  negative,  then  the  instrument  will  not  start  the 
Official Test or the Mandatory emission test.  
 
 
 

4.2.5  Test execution 

 

Follow the displayed instructions. 
Once  the  gas  sampling  probe  has  been  introduced,  the  programme 
automatically displays the steps to be followed. 
Bring the engine rpm to the indicated range and wait for the gas stabilization. 
At  the  end  of  the  test,  if  the  engine  rpm  values  have  not  been  properly 
detected, it is necessary to enter them manually. 
 
The test result is displayed at the end of it. 
 
Press the key 

 to go on. 

 
RESULT AT IDLE SPEED:   R 
 COc=0.1 % < 0.3 % 
RESULT AT MIN ACC:   R 
 COc=0.1 % < 0.2 % 

 

λ

=1.002   0.97-1.03

 

 
 
 
 
 
 

Summary of Contents for Smart Gas

Page 1: ...1161306 0 22 Quick Start Smart Gas Logic Gas Gas analyzer Operating manual ENGLISH Rev 2 0...

Page 2: ...____________________________________________30 4 2 Light test and gas official procedure _______________________31 4 2 1 Preliminary steps 31 4 2 2 Test start 31 4 2 3 HC test 32 4 2 4 Leak test 32 4...

Page 3: ...1161306 0 24 1 Package contents Gas analyzer Smart Gas Logic Gas 220V supply cable Serial cable for connection to the PC Exhaust gas sampling probe Logbook...

Page 4: ...lli After Market Parts and Services MM AM P S warrants the Product for 24 Twenty four Months starting from the date of the Product s activation or the date of the original purchase turning out by the...

Page 5: ...e Document The Product will be returned back to the Customer in Carriage Forward Shipment 2 4 Warranty Exclusions The Warranty does not extend to degraded Parts caused by the wrong using of the Equipm...

Page 6: ...ecking and verifying the Product will be charged to the Customer 3 Product installation Take the instrument out of the package and follow the procedure to carry out a vehicle first exhaust gas analysi...

Page 7: ...exhaust pipe whereas the other side shall be connected to the analyzer The instrument gas inlet is situated on the condensate separator Connect the gas sampling probe as shown in the picture Arrow key...

Page 8: ...alyzer Smart Gas switch on the display will show a short introduction message then the analyzer enters automatically in the main page where it is possible to select the type of test to be carried out...

Page 9: ...bar will indicate the operation progress The warm up average time is of 3 5 minutes depending on the environment temperature At the end of the WARM UP the pump turns on and the display shows the mess...

Page 10: ...ry steps Mandatory emission test you will be asked to select the vehicle engine type for any detail on the categories please refer to page 38 of the user manual Gas analysis Free page Light Test Offic...

Page 11: ...lt be negative then the instrument will not start the Official Test or the Mandatory emission test 4 2 5 Test execution Follow the displayed instructions Once the gas sampling probe has been introduce...

Page 12: ...guration menu when you want to change the settings date and time modification and each time you modify the used configuration for example when you pass form a rev counter with pliers to a M C T C NET...

Page 13: ...l message display at instrument switch on press the ESC or F function key if you are in the instrument main menu press the ESC key twice Select the Set up item and press the key to confirm Set up Serv...

Page 14: ...as values will remain displayed to facilitate the operation when you are connected with a computer Once the communication with the Computer is interrupted the instrument can be locally reused only aft...

Page 15: ...the installation of the Greek version Select the first item for all the other kinds of installation Only one of the 3 options can be selected If the product is installed with the Bluetooth option sele...

Page 16: ...de supplied with the CD it is written on the CD cover Do not carry out any operation until the end of the installation 7 Software use on PC Select the programme icon present on the desktop or which ca...

Page 17: ...etooth Pairing module In case the product is fitted with Bluetooth communication system with commercial Bluetooth module installed on the PC the wireless module shall be configured in order to associa...

Page 18: ...earch for nearby devices Select the required language Once the search is ended the window shown in the figure will be displayed If one or more products have been found in the area they will be highlig...

Page 19: ...as follows to clean the instrument Make sure that the multiple outlet switch is OFF WARNING Do not clean the inside part of the condensate separator chambers with alcohol Check the filter see picture...

Page 20: ...1161306 0 41 Clean the gas sam...

Reviews: