
Name
Vacuum 20
Enter the correct value using
UP-DOWN
buttons. Confirm by pressing
ENTER
. Display will
show the entered data.
Refrigerant qty g: 700
Vacuum: 20
Select
ENTER
to save the data. You will return to the user’s vehicles selection list.
8.3
Automatic program (with a memory card),
When entering the program selection mode (see
9 PROGRAMS
) the following menu
appears:
Auto Progr. ■
User progr. □
Select using
UP-DOWN
buttons.
Confirm by pressing
ENTER
.
Specify refrigerant weight ■
User vehicles □
Select using
UP-DOWN
buttons.
Confirm by pressing
ENTER
.
Specify refrigerant weight
Refrig. g XXXX
Specify the correct refrigerant weight using
UP-DOWN
buttons.
Confirm by pressing
ENTER
.
Refrigerant qty g: XXXXX
Vacuum: XX:XX
Vacuum generation time is calculated based on the refrigerant quantity specified.
Use
UP-DOWN
buttons to select the oil/UV injection program.
See
9.5 Programming oil/UV injection phase.
Confirm by pressing
ENTER
to start the automatic program with manual oil/UV injection.
8.3.1
Searching the vehicle model (Database)
Choose
select model
function to use the database.
Specify refrigerant weight ■
Select model □
Select using
UP-DOWN
buttons.
Confirm by pressing
ENTER
.
User vehicles