Page 1: ...Sp ka z o o Plac Pod Lipami 5 40 476 Katowice Tel 48 032 6036107 Fax 48 032 603 61 08 e mail checkstar magnetimarelli com www magnetimarelli checkstar pl Battery Electrical Tester with Printer BAT2000...

Page 2: ...TEST PROCEDURES OPERATING INSTRUCTIONS IMPORTANT 1 For testing 6 and 12 volt batteries and 12 and 24 volt charging systems ONLY 12 volt for START STOP battery test...

Page 3: ...2 Suggested operation range 32 F 0 C to 122 F 50 C in ambient temperature 1 2 3 4 5 6 7 Temperature Sensor Display Directional Keys USB Port Voltmeter Jack AMP Clamp Jack Printer...

Page 4: ...ime before using your tester please read these instructions very carefully 2 To reduce risk of battery explosion follow these instructions and those published by the battery manufacturer and manufactu...

Page 5: ...e risk of dropping a metal tool onto the battery It could spark or short circuit the battery or other electrical parts and could cause an explosion 7 Remove personal metal items such as rings bracelet...

Page 6: ...from vehicle to test always remove ground terminal from battery first Make sure all accessories in the vehicle are off to ensure you do not cause any arcing OPERATION USE 1 Remove the cover on the bac...

Page 7: ...ut 4pcs 1 5V batteries into the battery chamber Oxyride batteries are not recommended because of the initial 1 7 Volt output If the 1 5V battery runs out of power screen will show REPLACE INTERNAL BAT...

Page 8: ...ry terminal Clamp the red load lead to the vehicle positive battery terminal Please clamp on the lead part of the terminal only Clamping on the iron part of the terminal will lead to wrong test result...

Page 9: ...EM TEST 2 Press the key to select battery type a EFB ENHANCED FLOODED b AGM FLAT PLATE Press ENTER button to confirm choice 3 Press the key to select battery rating SAE CCA EN IEC or DIN Press ENTER b...

Page 10: ...he Temperature Measurement sensor 2 5cm 1 inch from the top or sides of the battery case and press ENETR Measured temperature may vary by distance from the battery under hood conditions and cabinet te...

Page 11: ...ndition cannot be determined until it is fully charged Recharge retest the battery The battery will not hold a charge It should be replaced immediately The battery has at least one cell short circuit...

Page 12: ...nected To print a 24V system test result user must save the test result first The test result will be saved until you connect to 12V battery The message to check printout will be displayed after you r...

Page 13: ...t data will be deleted 1 Press the key to select Battery Test In this stage you will find the 3 tests for selection START STOP BATTERY TEST SYSTEM TEST Press ENTER button to proceed the test for regul...

Page 14: ...capacity SAE CCA 40 3 000 EN 40 2 830 DIN 25 1 685 IEC 30 1 985 JIS Battery Type No Press ENTER to begin the test 5 Press the key to confirm the location of the battery if a surface charge is detecte...

Page 15: ...e display shows the results as following Press the key to select Temperature SOH STATE OF HEALTH and SOC STATE OF CHARGE 3 The battery is good and capable of holding a charge The battery is good but n...

Page 16: ...ircuit It should be replaced immediately NOTE Under certain conditions the follow messages may be displayed The tested battery is bigger than 3000 SAE CCA or the connection is not established Check th...

Page 17: ...records 1 000 test results After a 1 000 tests the tester will over write previous saved test data It is recommended to transfer the test data to a PC through the SYNC BAT2000 is unable to save the te...

Page 18: ...ng with the actual measured result The system is showing normal draw Press ENTER to perform the charging system test The cranking voltage is below normal limits troubleshoot the starter with manufactu...

Page 19: ...lternator is not providing sufficient current to the battery Check the belts to ensure the alternator is rotating with engine running If the belts are slipping or broken replace the belts and retest C...

Page 20: ...nnection and the ground connection is normal If there is no connection issue replace the regulator Since most alternators have the regulator built in this will require you to replace the alternator Th...

Page 21: ...eld wipers 8 When testing older model diesel engines the user need to run up the engine to 2500 rpm for 15 seconds You will see the run engine up instruction screen 9 Press ENTER to look for the amoun...

Page 22: ...ey to continue the charging system with accessory loads One of the three results will be displayed along with the actual testing measured The alternator is not providing sufficient current for the sys...

Page 23: ...tem is showing normal output from the alternator no problem detected The voltage output from the alternator to the battery exceeds the normal limits of a functioning regulator Check to ensure there ar...

Page 24: ...NTER and the display will show the language options Press the directional keys to select the language you want the tester to display 4 Press ENTER and the display returns to BATTERY TEST SETTING THE D...

Page 25: ...e directional keys to change the setting 7 Press ENTER and the display will show the ADJUST MINUTE Press the directional keys to change the setting 8 Press ENTER and the display will show the ADJUST S...

Page 26: ...ch BAT2000 comes with a CD including the driver of the software installation and its user guide You can follow the instruction to install the specific software for the diverse demand PC NAVIGATION GUI...