5.9.3 Clear History
Parameter
Name
Function
Range
Default
O03.01
Elapsed Time Setting
Accumulated operation time displayed in
monitor U04.01.
0000–9999hr
0000
O03.02
Elapsed Time Selection
Selects how the Elapsed Time is accumulated
00, 01
01
00 Power On Time
01 Running Time
O03.03
Fan ON Time Set
Sets the value of the Fan Operation Time
monitor (U04.03) in units of 10 hours. A setting
of 30 = 300 hours
0000–9999 x
10hr
0000
O03.05
Capacitor Maintenance
Setting
DC Bus Capacitors maintenance time displayed
in U04.05 as a percentage of the total expected
performance life.
000–150%
000
O03.07
Pre-Charge Relay
Maintenance Setting
Pre-Charge Relay maintenance time displayed
in U04.06 as a percentage of the total expected
performance life.
000–150%
000
O03.09
IGBT Maintenance Setting
IGBT maintenance time displayed in U04.07 as
a percentage of the total expected performance
life.
000–150%
000
O03.11
Fault Trace Clear
Clears Fault History
00, 01
00
00 Not Cleared
01 Clear U2/U3
O03.12
kWh Monitor Initial Value
Selection
Sets kWh Monitor Initial Value
00, 01
00
00 No Reset
01 Reset
O03.14
Clear Count History
Clears count history
00–03
00
00 Not Clear
01 Reset Runs
02 Clear OL/LC Count
03 Clear Both Counts