A1-5
SETTING RANGE
SETTING
FACTORY
USER
PARA.
CONSTANT
NAME
(AND UNITS)
INCREMENT
SETTING
SETTING
REF.
0: Detection Disabled
1: Detect only at set frequency;
operation continues
2: Detect only at set frequency;
Overtorque Detection (OL3)
coast to stop
1
0
3: Detect during all frequency conditions;
operation continues
4: Detect during all frequency conditions;
coast to stop
5.20
Overtorque Detection
Selection During Open Loop
0: Detected by output torque
1
0
Vector Control
1: Detected by output current
Overtorque Detection
Level (OL3)
30 to 200
1 (%)
160
Overtorque Detection
Delay Time (OL3)
0.1 to 10.0
0.1 (sec)
0.1
Up/Down Hold
0: Disabled
Memory
1: Enabled
1
0
5.10
Torque Compensation Gain
0.0 to 2.5
0.1
1.0
Torque Compensation
5.26
Time Constant
0.0 to 25.5
0.1 (sec)
Note 2
Torque Compensation
0.1 (W) or
Iron Loss
0.0 to 6550
1 (W)
Note 1
5.26
Motor Rated Slip
0.0 to 20.0
0.1 (Hz)
Note 1
5.22
n107
Motor Line-to-line
0.001 (ohm)
Resistance
0.000 to 65.50
Note 1
2.4A
n108
Motor Leakage
0.01 (mH)
Inductance
0.00 to 655.0
or 0.1 (mH)
Note 1
Torque Boost
1 (%)
(O.L.V. Only)
0 to 250
150
5.26
Motor No-load Current
0 to 99
1 (%)
Note 1
2.4A
Slip Compensation Gain
0.0 to 2.5
0.1
Note 2
Slip Compensation Primary
0.0 to 25.5
0.1 (sec)
Note 2
5.22
Delay Time
Slip Compensation Selection
0: Disabled
1
0
During Regeneration
1: Enabled
0: Disabled
n115
Stall Prevention Above Base
(level is based on setting of n094)
Speed During Run
1: Enabled
1
0
(level at Fmax is n094 x 0.4)
0: Follows acc/dec #1 (n019, n020)
or acc/dec #2 (n021, n022)
n116
Stall Prevention During Run,
Note: Multi-Function input selectable
1
0
Accel/Decel Time Select
1: Follows acc/dec #2 (n021, n022)
always
Frequency Reference 9
0.00
Frequency Reference 10
0.01 (Hz)
0.00
Frequency Reference 11
(< 100 Hz)
0.00
Frequency Reference 12
0.00 to 400.00
or
0.00
5.11
Frequency Reference 13
0.1 (Hz)
0.00
Frequency Reference 14
(>= 100 Hz)
0.00
Frequency Reference 15
0.00
Table A1-1. GPD 315 Parameters - Continued