DISPLAY MONITOR FUNCTIONS
66
CUBE
I.D. No.
HP
53ST***
Max Inpt
***Vac
1 002,
003
525
3 005,
007
525
6 010,
015
525
9 020,
025,
030
525
12 040,
050,
060
525
15 075,
100,
125
525
18 150 525
21 200 525
24 250 525
28 300 525
31 400 525
34 500 525
37 600 525
40 700 525
43 800 525
44 040,
050,
060
600
45 075,
100,
125
600
46 200 600
47 300 600
48 400 600
49 600 600
50 800 600
*** This number should agree with
the DSD 412 drive data nameplate.
Table 9: Cube I.D. Number
FIELD CURRENT RANGE (2 - 200HP)
Indicates actual SW1 setting
#689 SW1
Read-Back
Minimum
Rated Field
Amps DC
Maximum
Rated Field
Amps DC
1 0.2
1.9
3 7.0
16.0
6 2.0
6.9
8 16.1
40.0
FIELD CURRENT RANGE (250 - 800HP)
Indicates actual SW1 setting
#689 SW1
Read-Back
Minimum
Rated Field
Amps DC
Maximum
Rated Field
Amps DC
3 2.0
16.0
8 16.1
40.0
Table 10: Field Current Range
Summary of Contents for DSD 412
Page 1: ...DSD 412 DC Elevator Drive Technical Manual CS00407 rev 06...
Page 6: ...6...
Page 102: ...MAINTENANCE 102 Figure 24 Connector and E prom Locations...
Page 103: ...MAINTENANCE 103 Figure 25 Test Point Locations...
Page 115: ...OUTLINE DRAWING 100A 115 Figure 26 Drive Chassis Outline DSD 412 100 Amp...
Page 116: ...OUTLINE DRAWING 190A 116 Figure 27 Drive Chassis Outline DSD 412 195 Amp...
Page 117: ...OUTLINE DRAWING 300A 117 Figure 28 Drive Chasis Outline DSD 412 300 Amp...
Page 118: ...LAYOUT DRAWING 100A 118 Figure 29 Layout DSD 412 100 Amp A3 A1 A2 A2 L1 NEG GND L2 L3 POS...
Page 119: ...LAYOUT DRAWING 195A 119 Figure 30 Layout DSD 412 195 Amp A3 A1 A2 A2...
Page 120: ...LAYOUT DRAWING 300A 120 Figure 31 Layout DSD 412 300 Amp A3 A1 A2 A2...
Page 121: ......