(E) 5
2. Output Signal Alarm
If the response speed is exceeded, the phase A/B output from this measuring unit
changes to Hi level for about 400 ms to serve as an alarm.
3. Receiver
Line driver
Output: phase A/B/Z
Receiver
Line receiver
AM26C32 or equivalent
∗
If extending the cable, use with a supply voltage in the range from +5 V to
+5.25 V.
∗
Use the CE22 series extension cables for bare wires (optional accessories).
Alarm section
Phase A/B is Hi level
L
L
L
L
L
Optional Accessories
•
Air Lifter DZ-801
The air lifter is available for manual operation of the measuring rod.
Use it in combination with DK812LR/DK812LR5/DK802LR/DK802LR5.
•
Mounting Bush DZ-811 is optionally available to mount the measuring
unit on Gauge Stand DZ-501.
10 m/32.8' or less