Specifications and Site Requirements
Electrical Specifications
MagneMover LITE User Manual
57
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
AC Power Cable
The Node Controller LITE optional remote power supply is supplied with a power cable. Con-
tact MagneMotion for replacement cables. The AC power cable plugs directly into the power
supply. The remote power supply and AC cable for the Node Controller LITE is not required
if Power over Ethernet is being used.
Table 4-26: Node Controller LITE RS-422 Pinouts
Upstream
Downstream
J1, J3 - DE-9, Male
J2, J4 - DE-9, Female
—
1
—
1
RxD-
2
TxD-
2
TxD+
3
RxD+
3
—
4
—
4
—
5
—
5
—
6
—
6
RxD+
7
TxD+
7
TxD-
8
RxD-
8
—
9
—
9
2
3
7
8
7
8
2
3