background image

11

2PM

3PM

4PM

5PM

6PM

7PM

8PM

9PM

Timer starts 

Unit turns

 

Unit turns

 

 

ON

OFF

6 hours later

8 hours later

12

Setting both TIMER ON and TIMER OFF at the same time

Keep in mind that the time periods you set for both functions refer to hours after the

current time. For example, say that the current time is 1:00 PM, and you want the unit 

to turn on automatically at 7:00 PM. You want it to operate for 2 hours, then automa-

tically turn off   9:00 PM. 

Do the following:

ON/O

FF

ON/O

FF

MO

DE

MO

DE

SHO

RT

SHO

RT

CUT

CUT

TIMER ON

TIMER O

N

TEMP

TEM

P

sec

sec

4

8

3

7

X12

X16

2

6

1

5

TIMER ON

TIMER ON

TIMER OFF

TIMER OFF

 at

Example:

 

Setting

 

the

 

unit to

 

turn on  after 6 hours, operate

 

for 2 hours,

 

then

 

turn off

(see

 

the

 

figure

 

below)

 

Your

 

remote

 

display

 

 

Timer on

 

 

Timer is set  to turn ON 

 

6 hours from current time

 

 

Timer off

 

 

Timer is set to turn OFF 

 

8 hours from current time 

Summary of Contents for RG57H/BG

Page 1: ... manual carefully before using your air conditioner REMOTE CONTROL MANUAL AIR CONDITIONER For any service needs call 1 855 368 8606 MAGNAVOX and SMART VERY SMART are registered trademarks of Koninklijke Philips N V and are used under license from Koninklijke Philips N V ...

Page 2: ...H B BGE 23 F 140 F 4 Handling the remote control 2 Remote Control Specifications 3 Function buttons 5 Remote LCD screen indicators 6 How to use the basic functions 13 How to use the advanced functions Remote Control Specifications ON OFF TEMP SHORT CUT TIMER ON TIMER OFF MODE FAN SLEEP SWING LED RG57H B BGE ...

Page 3: ...ore than 2 months Inserting and Replacing Batteries Your air conditioning unit comes with twoAAA batteries Put the batteries in the remote control before use 1 Slide the back cover from the remote Control downward exposing the battery compartment 2 Insert the batteries paying attention to match up the and ends of the batteries with the symbols inside the battery compartment 3 Slide the battery cov...

Page 4: ...range 0 24 hours This display is blank when operating in FAN mode Remote LCD Screen Indicators ON OFF ON OFF TEMP TEMP SHORT CUT SHORT CUT TIMER ON TIMER ON TIMER OFF TIMER OFF MODE MODE FAN FAN SLEEP SLEEP LED LED SWING SWING How To Use The Basic Functions SETTING TEMPERATURE The operating temperature range for units is 62 F 86 F You can increase or decrease the set temperature in 1 F increments ...

Page 5: ...se The Basic Functions ON OFF TEMP SHORT CUT TIMER ON TIMER OFF MODE FAN LED ON OFF TEMP SHORT CUT TIMER ON TIMER OFF MODE FAN SLEEP LED ON OFF TEMP SHORT CUT TIMER ON TIMER OFF MODE FAN SLEEP LED SLEEP SWING SWING SWING How To Use The Basic Functions DRY operation dehumidifying 1 Press the MODE button to select DRY mode 2 Set your desired temperature using the Temp or Temp button 3 Press the ON O...

Page 6: ...st time period that you set and an h indicating hours will appear on the display Note 2 0h 2sec x10 ON OF F MO DE FA N SH OR T CU T TIM ER ON TIM ER OF F TE MP SLE EP 1sec 1 3 2 4 TIMER ON TIMER ON TIMER OFF TIMER OFF Continue to press TIMER ON or TIMER OFF until desired time is reached Setting the TIMER function Your air conditioning unit has two timer related functions TIMER ON sets the amount o...

Page 7: ...nit to turn on automatically at 7 00 PM You want it to operate for 2 hours then automa tically turn off 9 00 PM Do the following ON OFF ON OFF MO DE MO DE SH OR T SH OR T CU T CU T TIME R ON TIME R ON TE MP TE MP sec sec 4 8 3 7 X12 X16 2 6 1 5 TIMER ON TIMER ON TIMER OFF TIMER OFF at Example Setting the unit to turn on after 6 hours operate for 2 hours then turn off see the figure below Your remo...

Page 8: ...ada it should comply with CAN ICES 3 B NMB 3 B In USA this device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interfe rence and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class...

Page 9: ......

Reviews: