INSTALLATION  INSTRUCTIONS

Water drainage:

-    During dehumidifying modes, remove the drain 
     plug from the back of the unit, install the drain 
     connector(5/8  universal female mender) with 
     3 4  hose(locally purchased). For the models
     without drain connector, just attach the drain 
     hose to the hole. Place the open end of the 
     hose directly over the drain area in your 
     basement floor. Please refer to Fig.22 &  23.

-    When the water level of the bottom tray reaches 
     a predetermined level,

     Carefully move the unit to a drain location, 
     remove the bottom drain plug and let the
     water drain away(Fig.24).  Restart the machine 

 and wait for the  P1  symbol to disappear. 

If the error  continues, call for service.

 

the unit beeps 8 times, 

     the digital display area shows  P1 . At this time
     the air conditioning/dehumidification process will 
     immediately stop. However, the fan motor will 
     continue to operate(this is normal).

Remove the 

drain plug

Continuous 

drain hose

Fig.22

Fig.23

 NOTE: Be sure to reinstall the bottom drain plug

 before using the unit.

    

13

Fig.24

Summary of Contents for P-14PE

Page 1: ...Before operating this product please read the instructions carefully and save this manual for future use MODEL P 14PE For any service needs call 1 855 368 8606 OWNER S MANUAL...

Page 2: ...by a responsible adult or considered capable enough to operate the appliance safely Children should be supervised to ensure that they do not play with the appliance If the supply cord is damaged it m...

Page 3: ...ontrol panel operating instructions 5 Operating instructions 6 Placement 8 Window kit installation 8 Exhaust hose installation 12 Water drainage 13 Care and maintenance 14 Troubleshooting tips 15 AIR...

Page 4: ...operly or if it has been dropped or damaged Never use the power plug to turn unit on or off Do not cover or obstruct the inlet or outlet grilles Do not use hazardous chemicals to clean or come into co...

Page 5: ...rs and liquids in the vicinity of this or any other appliance Avoid fire hazard or electric shock Do not use an extension cord or an adaptor plug Do not remove any prong from the power cord WARNING El...

Page 6: ...4 5 Model A Model B Control Panel Horizontal Louver Blade operate manually Remote signal receptor Caster wheels Carrying Handles on each side 1 2 3 4 5 Fig 1 Rear 6 7 8 9 10 11 Upper Air Filter Behin...

Page 7: ...the same time for 3 seconds 3 Used to initiate the AUTO ON start time and AUTO OFF stop time program in conjuction with the buttons TIMER button 4 Used to initiate the SLEEP mode SLEEP button 6 2 Powe...

Page 8: ...e temperature you have selected and thecurrent room temperature While the unit is on press the Timer button the TIMER OFF indicator light illuminates This indi cates the Auto Stop program is initiated...

Page 9: ...the louver s doing o will cause damage to the unit Ensure the louver is fully opened during heating operation Adjust the air flow direction automatically Fig 6 When the unit is turned ON the louver o...

Page 10: ...for easy mobility but it should only be rolled on smooth flat surfaces Use caution when rolling on carpet surfaces Do not attempt to roll the unit over objects The unit must be placed within reach of...

Page 11: ...window is less than 26 5 inches Open the window sash and place the window slider kit on the window sill See Fig 11 3 Cut the foam seal adhesive type to the proper length and attach it on the top of t...

Page 12: ...f the width of window is less than 26 5 inches Open the window sash and place the window slider kit on the window sill See Fig 15 3 Cut the foam seal adhesive type to the proper length and attach it o...

Page 13: ...d the window sill when there is the gap between them as shown below Window kit Window sill Fig A Gap Window kit Window sill Fig A1 White foam seal Seal the white foam seal Window kit Gap Window frame...

Page 14: ...e previous pages for window kit installation 2 Place the Exhaust hose over against the air outlet opening hook See Fig 19 and flat the other end See Fig 20 for quick installation IMPORTANT DO NOT OVER...

Page 15: ...r level of the bottom tray reaches a predetermined level Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Fig 24 Restart the machine and wait for t...

Page 16: ...er on the air inlet grille then install the grille by using the screw 2 Unit enclosure Use a lint free cloth soaked in neutral detergent to clean the unit enclosure Finish with a dry clean cloth 3 Uni...

Page 17: ...dust 2 Not cool enough Place the unit on a flat level ground if possible This is normal The ground is not level or not flat enough The sound comes from the flowing of the refrigerant inside the air c...

Page 18: ...MAGNAVOX and SMART VERY SMART are registered trademarks of Koninklijke Philips N V and are used under license from Koninklijke Philips N V...

Reviews: