background image

11

Operation

Other features

FOLLOW ME/TEMP SENSING feature(optional)

NOTE:This feature can be activated from the remote control ONLY. The remote control 

overseas a remote thermostat allowing for the precise temperature control at its location.

To activate the Follow Me/Temp Sensing feature, point the remote control towards the 

unit and press the Follow Me/Temp Sensing button. The remote display is actual 

temperature at its location. The remote control will send this signal to the air conditioner 

every 3 minutes interval until press the Follow Me/Temp Sensing button again. If the unit 

does not receive the Follow Me/Temp Sensing signal during any 7 minutes interval, the 

unit will beep to indicate the Follow Me/Temp Sensing mode has ended. 
AUTO-RESTART

If the unit breaks off unexpectedly due to the power cut, it will restart with the previous 

function setting automatically when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING OPERATION

After the unit has stopped, it cannot be restarted operation in the first 3 minutes. This is 

to protect the unit. Operation will automatically start after 3 minutes. 

AIR FLOW DIRECTION ADJUSTMENT

The louver can be adjusted automatically. Adjust the air flow direction automatically (NOTE:

On some models the louver can be adjusted manually only) :

-When the Power is ON, the louver opens fully.

-Press the SWING button on the panel or remote control to initiate the Auto swing  

 feature. The louver will swing up and down automatically.

-Please do not adjust the louver manually.

Water drainage

-During dehumidifying modes, remove the 

 upper drain plug from the back of the unit, 

 install the drain connector(5/8" universal 

 female mender) with 3/4" hose(locally 

 purchased). For the models without drain 

 connector, just attach the drain hose to the 

 hole. Place the open end of the hose directly 

 over the drain area in your basement floor,

 or into a bucket.

Remove the 

upper drain plug

Continuous 

drain hose

-When the water level of the bottom tray reaches 

 a predetermined level, the unit beeps 8 times, 

 the digital display area shows "P1" . At this time

 the air conditioning/dehumidification process will 

 immediately stop. However, the fan motor will 

 continue to operate(this is normal). Carefully move 

 the unit to a drain location, remove the bottom drain 

 plug and let the water drain away. Reinstall the bottom

 drain plug and restart the machine until the "P1" 

 symbol disappears. If the error repeats, call for 

 service.

 NOTE: Be sure to reinstall the bottom drain plug firmly 

             to prevent leakage before using the unit.

-Press this button, the selected temperature will increase(cooling) or decrease(heating) by 

 1°C/1°F 30 minutes.The temperature will then increase (cooling) or decrease (heating) by 

 another 1°C/1°F after an additional 30 minutes. This new temperature will be maintained 

 for 7 hours before it returns to the originally selected temperature. This ends the Sleep/Eco 

 mode and the unit will continue to operate as originally programmed. 

 NOTE: This feature is unavailable under FAN or DRY mode.

    

SLEEP/ECO operation

Summary of Contents for P-12NPE

Page 1: ...For any service needs call 1 855 368 8606 OWNER SMANUAL MODEL P 08NPE P 12NPE P 14NPE...

Page 2: ...Contents 1 Preparation 2 Precautions Cautions Installation Operation 9 Maintenance Faults Diagnosis Design and Unit Temperature Range Safety 3 4 5 12 13 14...

Page 3: ...orizontal louver blade Caster power plug socket power cord buckle bottom tray drain outlet power cord outlet drain outlet only for pump heating mode upper air filter behind the grille upper air intake...

Page 4: ...o mitigate safety hazards DO NOT modify the length of the power cord or use an extension cord to power the unit DO NOT share a single outlet with other electrical appliances Improper power supply can...

Page 5: ...ith throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not operate unit with a damaged...

Page 6: ...d 5 Your installation location should meet the following requirements Make sure that you install your unit on an even surface to minimize noise and vibration The unit must be installed near a grounded...

Page 7: ...let and slide down the Exhaust hose assembly along the arrow direction for installation Hook Hole Seat Lower groove adaptor Make sure the adaptor is inserted into the lower groove of the air outlet Un...

Page 8: ...between the glass and the window frame to prevent air and insects from getting into the room If desired install the security bracket with 2 screws as shown Insert the window slider assembly into the w...

Page 9: ...e hose Make sure that there is no obstacle around the air outlet of the exhaust hose in the range of 19 69inch in order for the exhaust system works properly All the illustrations in this manual are f...

Page 10: ...t illuminates under the timer on off settings Mode button Selects the appropriate operating mode Each time you press the button a mode is selected in a sequence that goes from AUTO COOL DRY and FAN Th...

Page 11: ...lay it will stay like this until the unit is drained if this happens you should drain the water from the lower drain located at the bottom of the unit The top drain is used only if you choose DRY mode...

Page 12: ...feature The louver will swing up and down automatically Please do not adjust the louver manually Water drainage During dehumidifying modes remove the upper drain plug from the back of the unit instal...

Page 13: ...mold In households with animals you will have to periodically wipe down the grill to prevent blocked air ow due to animal hair Remove the air filter Upper filter take out lower filter B take out lowe...

Page 14: ...nnected or is blocked The Water Collection Tray is full Turn off the unit drain the water from the Water Collection Tray and restart the unit There are heat sources inside the room Turn off the unit a...

Page 15: ...order to ensure the optimal performance of our products the design speci cations of the unit and remote control are subject to change without prior notice Unit Temperature Range 14 Cool 17 35 C 62 95...

Page 16: ......

Reviews: