10

Operation

LED display

- Shows the set temperature in °C or °F and the Auto-timer settings. 

- While on DRY and FAN modes, it shows the room temperature.

- Shows Error codes and protection code:

E1-Room temperature sensor error.

E2-Evaporator temperature sensor error.

E3-Condenser temperature sensor error (on some models).

E4-Display panel communication error.

E7-Zero-crossing malfunction.

P1-Bottom tray is full--Connect the drain hose and drain the collected 

water away. If this error repeats, call for service.

Note: When one of the above malfunctions occurs, turn off the unit, 

and check for any obstructions. Restart the unit, if the malfunction is 

still present, turn off the unit and unplug the power cord. Contact the 

manufacturer or its service agents or a similar qualified person for 

service.

 

Operation Instructions

Self-Evaporation System

COOL operation

-Press the "MODE" button until the "COOL" indicator light comes on.

-Press the ADJUST buttons "+" or "-" to select your desired room temperature. The 

 temperature can be set within a range of 17°C~30°C/62°F~86°F.

-Press the "FAN SPEED" button to choose the fan speed.

DRY operation

-Press the  "MODE" button until the  "DRY" indicator light comes on.     

-In cool mode, this unit is made to self-evaporate. This means, if you keep the rubber 

 stoppers closed on the back of the unit, the water will evaporate and you will not have 

 to drain.

-In cases of extreme humidity you may have some water accumulation that the unit is

 unable to evaporate, in this case the unit will beep 8 times, switch to fan mode and 

-Under this mode, you cannot select a fan speed or adjust the temperature. The fan

 motor operates at  LOW speed.

-Keep windows and doors closed for the best dehumidifying effect.

-Do not put the duct to window.

     

 read a p1 error on the display (it will stay like this until the unit is drained) if this 

 happens, you should drain the water from the lower drain (located at the bottom of 

 the unit).

-The top drain is used only if you choose DRY mode.

* Self Evaporation System works in COOL mode only
AUTO operation

-When you set the air conditioner in AUTO mode, it will automatically select cooling, 

 heating(cooling only models without), or fan only operation depending on what  

 temperature you have selected and the room temperature.

-The air conditioner will control room temperature automatically around the temperature 

 point set by you.

-Under AUTO mode, you cannot select the fan speed.

FAN operation

-Press the  "MODE" button until the "FAN " indicator  light comes on. 

-Press the "FAN SPEED" button to choose the fan speed. The temperature cannot be 

 adjusted.

-Do not put the duct to window.

TIMER operation

- While the unit is on, press the TIMER button, the TIMER OFF indicator light illuminates. 

  This indicates the AUTO OFF STOP program is initiated. Press the UP or DOWN button 

  to select the desired time. Press the TIMER button again within 5 seconds, the TIMER 

  ON indicator light illuminates. This indicates the AUTO ON START program is initiated. 

  Press the UP or DOWN button to select the desired time.

- While the unit is off, press the TIMER button to initiate the AUTO ON START program. 

  Press the TIMER button again within 5 seconds to initiate the AUTO OFF STOP program.

-Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up 

 to 10 hours, then at 1 hour increments up to 24 hours. The control  will count down the 

 time remaining until start. 

-The system will automatically revert back to display the previous temperature setting if 

 there is no operation in a 5 seconds period.

-Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the 

 Auto Start/Stop timer program.

-When the malfunction occurs, the Auto Start/Stop timed program will also be cancelled.

Summary of Contents for P-12NPE

Page 1: ...For any service needs call 1 855 368 8606 OWNER SMANUAL MODEL P 08NPE P 12NPE P 14NPE...

Page 2: ...Contents 1 Preparation 2 Precautions Cautions Installation Operation 9 Maintenance Faults Diagnosis Design and Unit Temperature Range Safety 3 4 5 12 13 14...

Page 3: ...orizontal louver blade Caster power plug socket power cord buckle bottom tray drain outlet power cord outlet drain outlet only for pump heating mode upper air filter behind the grille upper air intake...

Page 4: ...o mitigate safety hazards DO NOT modify the length of the power cord or use an extension cord to power the unit DO NOT share a single outlet with other electrical appliances Improper power supply can...

Page 5: ...ith throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not operate unit with a damaged...

Page 6: ...d 5 Your installation location should meet the following requirements Make sure that you install your unit on an even surface to minimize noise and vibration The unit must be installed near a grounded...

Page 7: ...let and slide down the Exhaust hose assembly along the arrow direction for installation Hook Hole Seat Lower groove adaptor Make sure the adaptor is inserted into the lower groove of the air outlet Un...

Page 8: ...between the glass and the window frame to prevent air and insects from getting into the room If desired install the security bracket with 2 screws as shown Insert the window slider assembly into the w...

Page 9: ...e hose Make sure that there is no obstacle around the air outlet of the exhaust hose in the range of 19 69inch in order for the exhaust system works properly All the illustrations in this manual are f...

Page 10: ...t illuminates under the timer on off settings Mode button Selects the appropriate operating mode Each time you press the button a mode is selected in a sequence that goes from AUTO COOL DRY and FAN Th...

Page 11: ...lay it will stay like this until the unit is drained if this happens you should drain the water from the lower drain located at the bottom of the unit The top drain is used only if you choose DRY mode...

Page 12: ...feature The louver will swing up and down automatically Please do not adjust the louver manually Water drainage During dehumidifying modes remove the upper drain plug from the back of the unit instal...

Page 13: ...mold In households with animals you will have to periodically wipe down the grill to prevent blocked air ow due to animal hair Remove the air filter Upper filter take out lower filter B take out lowe...

Page 14: ...nnected or is blocked The Water Collection Tray is full Turn off the unit drain the water from the Water Collection Tray and restart the unit There are heat sources inside the room Turn off the unit a...

Page 15: ...order to ensure the optimal performance of our products the design speci cations of the unit and remote control are subject to change without prior notice Unit Temperature Range 14 Cool 17 35 C 62 95...

Page 16: ......