background image

MAGNASPHERE   N22 W22931 Nancys Ct. Ste 3, Waukesha, WI 53186     tel 262.347.0711     fax 262.347.0710      www.magnasphere.com

Additional mounting hardware, resistor configurations, cable lengths, and other variants are available.

Patents #5673021, #6603378, #8228191, #8314698 & Patents Pending

MAGNASPHERE L2X-800 INSTALLATION INSTRUCTIONS: All Models of (L2X) 800-Series  [Page:1]

CAUTION: MAGNASPHERE MAGNET MODULES AND ANTI-REMOVAL MAGNETS ARE EXTREMELY POWERFUL: TAKE PRECAUTIONS TO AVOID THE MAGNETIC ATTRACTION OF 

SHARP TOOLS AND TO AVOID INJURY FROM THE PINCHING FORCE BETWEEN THE MAGNET AND FERROUS METALS OR OTHER MAGNETS

.

Required Tools and Components

Provided by Manufacturer (per module set)

1 L2X switch module

1 L2X magnet module

7 switch & magnet module self-tapping screws (#10-32 x 2")

1 self-tapping screw (#6, 1" long)

2 1/16" plastic spacer plates

1 Removal-Tamper magnet

2 Removal-Tamper caps

1 1/2" NPT Plug

(P/N: SP062)

Provided by Installer

Intrinsically Safe Barrier (Listed to at least the Hazardous Location Class)

Power drill

Drills bits: #35,#21

Phillips screwdriver or a Phillips bit for use in the drill/bit-driver

Rule (or any linear measuring instrument)

A center punch (& hammer) for more accurate hole locations may be used

A pilot drill bit for screws (3/32" or smaller) may be used

Additional 1/16” SPACERS (10/ BAG – MAGNASPHERE P/N SP062)

Adjustable wrench

Pipe wrench 

Thread Locking Compound 

or a lockable N.P.T plug

 (see p.2 #3, note) 

Rigid 1/2" NPT Conduit (18" Min. per UL634 Level 2 Standard)

Installation Plan

Plan to mount the switch module to the door frame, close to the door/frame gap and without door-swing 

interference. The magnet module should be mounted directly below the switch.  Spacers may be used to 

attain sufficient alignment of the modules.  Recommended placement for the set is 8 inches from the latch 

side of the door, at the top.  The operating gap must not exceed 3/16".  Provided templates may assist 

locating holes.  *

A gap up to 1/8" is required for compliance with UL634 Level 2 high security standard.

Mark & pilot-drill all hole locations.  Drill the 3 mounting hole locations for the #10 screw (#21 bit).  

Drill the 

Removal-Tamper screw location for the #6 screw (#35 bit).

  Hold the switch module in position: Drive each 

screw in until seated, securing the device.

       CAUTION: Magnasphere's magnet module and anti-removal magnet are extremely powerful: Take 

precautions to avoid the magnetic attraction between the magnet and ferrous metals (or other 

magnets)

.  Align the magnet module directly below the switch module.  Determine whether spacers are 

needed to achieve mounted alignment of the modules.  Hold the magnet module and any spacers in position 

and drill the 4 hole locations for #10 screws (#21 bit).  Drive each screw in until seated, securing the device.  

Insert the Removal-Tamper magnet and then the Removal-Tamper plug into the 3/8" hole at the face of the 

switch module.  Check that the gap between modules is no greater than 1/8".  The mechanical installation of 

the set is complete.

DOOR FRAME

DOOR

SWITCH

MODULE

MAGNET

MODULE

DOOR

SWING

UP TO 

3/16" 

GAP*

Wrench Note

Recommended:

 Pre-Fasten an 1/2” NPT conduit section

to the Switch Module in order to prevent excessive stress. 

Wrench 

X

Wrench 

Specifications

Max Current:   

0.25 A Resistive

Max Voltage:   

30 VDC

Max Power:   

.25 W Resistive

Suitable for outdoor use.

The Magnasphere HSS Level 2 series 

is intended to be connected to a UL 

Listed compatible control panel for US 

applications and a ULC Listed 

compatible control panel for Canadian 

applications

.

Closed 

Open 

Common

Supervise

d

Common
Magnet

Tamper

Pry 

Tamper

ALARM

TAMPER

CIRCUT

WHT

RED

BLK

GRN

YEL

BLU

SC

SC

MT

PT

L2S Series

Resistors are Optional 

Supervise

d

Common
Magnet

Tamper

Pry 

Tamper

TAMPER

CIRCUT

GRN

YEL

BLU

Closed 

Common

ALARM

WHT

SC1

MT

PT

Closed 

Common

ALARM

ORN

SC2

PUR

BLK

L2D Series

Resistors are Optional 

Test the Magnet-Tamper circuit 

here with a powerful magnet

Remove to test the 

Pry Tamper circuit

SWITCH MODULE

#10 SCREW

#10 SCREWS

#10 SCREWS

MAGNET MODULE

1/16" SPACER

1/16" SPACER

REMOVAL

TAMPER

MAGNET

REMOVAL

TAMPER

CAP

#6 SCREW

#10 SCREWS

1/2" NPT PLUG

22 AWG (36" L)

(Longer leads can be ordered)

Attention: modules à aimants Magnasphere et anti-enlèvement aimants sont très puissants: prendre des précautions pour éviter l'attraction magnétique d'outils 

tranchants et à éviter les blessures de la force de pincement entre l'aimant et les métaux ferreux ou d'autres aimants.

Patents: #5977873, #6506987, #6803845, #7291794, #7944334, #8314698, #6087936, #6603378, #7023308, #RE39731, #8228191, #8648720 & Other Patents Pending