EN
www.magmaweld.com
ID 250TW DC
19
USER MANUAL | KULLANIM KILAVUZU
3.2 TIG Cycle
3.3 Menu Structure
The statuses of the functions on or off according to the modes are as follows.
3.3.1 TIG Welding Process
• 10 jobs programs including complete parameter settings can be stored and run for repeated jobs.
• In the first use, all parameters of all programs are in factory settings which are shown in the table.
• Push the program selection button
[3]
. For selecting a previously adjusted program or changing its parameters.
• Push the welding mode selection button
[5]
for selecting Touch-Lift TIG of HF start TIG.
• Use TIG parameter selection button
(13-14)
to change to welding parameters. When the led, which belongs to the parameter you will change is
turned on, adjust the parameter by turning the parameter adjustment button.
• Latest adjusted parameter values will be saved automatically. There is no need to do anything else for saving the settings.
In HF Start TIG mode, a high ignition voltage is present at the torch. Never touch the tungsten electrode or parts condu-
cting welding current when the device is switched on.
Operation