2.1 Delivery Control
Symbols and their meanings on the device;
2.2 Installation And Operation Recommendations
To unpack your purchased welding machine to comply with the truck transport regulations, first tear the cutter, then cut the ring and lift the machine
down the pallet to comply with the truck transport regulations. Make sure you receive your order in full. If any material is missing or damaged, contact
your place of purchase immediately.
The standard package includes:
• Main machine and connected mains cable
• Warranty certificate
• Grounding clamps and cable
• User manual
In the case of a damaged delivery, draw up a record, take a picture of the damage and report to the transport company together with a photocopy of
the delivery note. If the problem persists, contact the customer service.
• Necessary precautions should be taken during transportation of the machine. Do not lift the machine with the gas cylınder. Place the power
supply on a hard, level and level surface where it will not fall or tip over.
• For better performance, place the machine at least 30 cm away from surrounding objects. Pay attention to overheating, dust and moisture around
the machine. Do not operate the machine in direct sunlight. When the ambient temperature exceeds 40°C, operate the machine at a lower current
or at a lower cycle rate.
• Avoid welding with wind and rain outdoors. If welding is required in such cases, protect the welding area and the welding machine with curtains
and awnings.
• When positioning the machine, make sure that materials such as walls, curtains, panels, etc. do not impede easy access to the controls and
connections of the machine.
• If welding inside, use a suitable smoke extraction system. Use breathing apparatus if there is a risk of inhaling welding fumes and gas indoors.
• Observe the duty cycle rates specified on the product label. Frequent exceeding duty cycle rates can damage the machine and void the warranty.
• Use the appropriate fuse for your system.
• Connect the ground wire as close to the welding area as possible. Do not allow welding current to pass through elements other than welding
cables, eg the machine itself, the gas cylinder, the chain, the bearing.
• When the gas cylinder is placed on the machine, immediately fasten the chain to secure the gas cylinder. If you do not place the gas cylinder on
the machine, fasten it to the wall with a chain.
• The electrical outlet on the back of the machine is for the CO₂ heater. NEVER connect a device other than a CO₂ heater to the CO₂ socket!
Welding process is dangerous. Proper working conditions should be ensured and necessary precautions should be taken. Specialists are
responsible for the machine and have to be equipped with the necessary equipment. Irrelevant persons should be kept away from the
welding area.
This device is not compatible with IEC 61000-3-12. If it is desired to connect to the low voltage mains used in homes, it is essential that the
installer or the person who will operate the machine to make the electrical connection has information on the machine’s connectivity. In
this case the responsibility will be assumed by the person who will perform the installation or by the operator.
The safety symbols and warning notes on the device and in the operating instructions must be observed and the labels must not be
removed.
Grids are intended for ventilation. The openings should not be covered in order to provide good cooling and no foreign objects should be
inserted.
INSTALLATION
Installation