EB3600-P | Chapter 6 Rack Slide Installation
88
CAUTION
Elevated Operating Ambient Temperature
:
If the expansion is installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack environment might be
greater than room ambient temperature. Therefore, consideration should be given to installing
the equipment in an environment compatible with the maximum ambient temperature (Tma)
specified for the expansion.
CAUTION
Reduced Air Flow
: Installation of the equipment in a rack should be such that the amount
of air flow required for safe operation of the equipment is not compromised
CAUTION
Circuit Overloading:
Consideration should be given to the connection of the equipment
to the supply circuit so that overloading of the circuits does not compromise the supply wiring
or over current protection. To provide the correct power connection to a rack, refer to the
rating labels located on the equipment in the rack to determine the total power requirement
of the supply circuit.
CAUTION
Reliable Earthing:
Reliable earthing of rackmounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connections to the
branch circuit (for example, use of power strips).
Tools and Supplies Needed
1.
Phillips* (cross head) screwdriver (#1 bit and #2 bit)
2.
Measuring Tape
Parts List
2 - Slide Rails
4 - End Brackets (2-long, 2-short)
2 - Bags of Assorted Nuts & Bolts
Summary of Contents for ExpressBox EB3600-P
Page 1: ...EB3600 P User Manual PCIe to PCIe Expansion MODEL EB3600 P...
Page 13: ...Magma EB3600 P Chapter 1 Introduction 13...
Page 32: ...Magma EB3600 P Chapter 2 Hardware Installation 32...
Page 33: ...Magma EB3600 P Chapter 2 Hardware Installation 33...
Page 37: ...Magma EB3600 P Chapter 2 Hardware Installation 37...
Page 92: ...Magma EB3600 P Chapter 6 Rack Slide Installation 92...
Page 106: ...Manual P N 09 09957 01 Rev A2...