background image


 

Maintenance and Inspection 

 

The user is obliged to maintain and service the drill stand and the drilling machine and in compliance with the 
specifications in the operation manual and according to the country-specific standards and regulations.  

 

The maintenance intervals are classified according to the frequency with which the maintenance should be carried 
out.  

 

 

Always disconnect the machine from the mains before any maintenance operation; otherwise 
there is a risk of injury due to unintentional machine switch-on.  

 

 
Before every use... 
 

 

inspect the core drilling machine, drill stand and underside of the magnet for visible signs of damage 

 

clean the surface of the workpiece and the underside of the magnet 

 

check the blocking function of the safety tab on the lever   

 
 
Weekly... 

 

 

check that the operating lever and safety tab are working properly 

 

check the underside of the magnet for scratches, pressure points or cracks. Have the magnet repaired by 
the manufacturer if necessary 

 
 
Monthly... 
 

 

check the markings and labelling on the drill stand for legibility and damage. Replace them if necessary 

 

clean all the sliding surfaces regularly, re-lubricate them and set the pre-tension of the slide  

 
 
 
 

Maintenance, testing and repair work may only be carried out by qualified electricians according to the regulations 
valid in the respective country. 
 

 

 

Only use genuine Maglogix

®

 spare parts. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for MagnaDrill MX-V

Page 1: ...Operation Manual MagnaDrill MX V Universal Magnetic Drill Stand ...

Page 2: ...e 10 Technical Data Available Accessories 11 Description 12 Start up 13 Special Information on Handling Switchable Permanent Magnets 14 Maintenance and Inspection 15 CE Declaration of Conformity 16 Before use read and save these instructions ...

Page 3: ...peration manual familiarise new users with the safe use of the machine wear safety goggles and ear protection during work use safety guard if supplied observe local country specific guidelines store in a dry place Never drill without first having activated the magnet work on round or curved objects drill several workpieces on top of one another modify the machine or remove signs use the machine wh...

Page 4: ... Collar Ø 43 mm Euro standard Ø 1 69 Euro standard Max drilling Ø in steel Core drill Twist drill 12 35 mm up to Ø13 mm DIN 338 1 3 8 Stroke 105 mm 80 mm height adjustment at slide 4 1 8 31 8 height adjustment at slide 3 Size of magnetic base 72 x 190 mm 2 x 7 Magnetic holding force 7500 N 1686 lbs Tool force on 10 mm steel 2800 N 630 lbs 3 8 steel Tool force on 6 mm steel 2300 N 520 lbs 2 8 steel...

Page 5: ...be vertically adjusted using the star handle H Wired mains operated drilling machines can be fixed tightly to this collar Ø 43 mm As an additional torque support there is a nose on the collar in order to engage the drilling machine into the collar The type plate and an attachment possibility for the Allen keys included can be found on the back of the machine A Tool holder Ø 43 mm G Lever for magne...

Page 6: ...g unit using the safety belt when working on walls and ceilings 4 Press the lever down as far as it will go Make sure that the safety tab audibly latches into place The magnet is now activated Before drilling make sure that the lever of the magnet is in the ON position 5 After having activated the magnet insert the plug of the drilling machine in the mains socket and turn the motor on 6 Turn the s...

Page 7: ...aper together in a circular pattern with many small lightweight staples close together and bending the legs together to achieve an even greater holding force An infinate number of small magnetic field arrays are the principle behind the Maglogix patented switchable magnetic clamps Material Every material reacts in different ways to the penetration of magnetic field lines The breakaway force of the...

Page 8: ...nd underside of the magnet for visible signs of damage clean the surface of the workpiece and the underside of the magnet check the blocking function of the safety tab on the lever Weekly check that the operating lever and safety tab are working properly check the underside of the magnet for scratches pressure points or cracks Have the magnet repaired by the manufacturer if necessary Monthly check...

Page 9: ...he universal magnetic drill stand MagnaDrill MX V corresponds to the following directives Machinery Directive 2006 42 EC Following directives or normative documents were applied Machine safety DIN EN ISO 12100 2011 Authorized for the compilation of the documents Alfra GmbH 2 Industriestr 10 68766 Hockenheim Germany Hockenheim 15 11 2017 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...12 Maglogix LLC 11196 Cardinal Drive Parker CO 80138 Phone 303 257 7888 Internet www maglogix com Email info maglogix com 11 2017 ...

Reviews: