Beam Patterns

The PMD85 series features the following beam patterns:

Installation

After selecting the detector’s location, drill or punch out holes for the mounting screws 

as shown in Figure 1.

Avoid placing the detector within proximity of sources of interference such as direct 

sunlight, reflective surfaces and moving cars. Do not mount the detector near or on 

metal, such as aluminum siding, as this may affect signal transmission.

The PMD85 can also be mounted using the Paradox Swivel Mount Bracket 

(469). The swivel mount may allow for easier mounting. If using the swivel 

mount, it is recommended that you seal the space where the swivel mount is 

connected to the back cover with some silicon or with a rubber gasket to ensure 

that moisture does not enter the detector.

After you have installed the detector, ensure that the adjustable height markings on the 

upper right of the PCB’s cover inside the unit match the installation height (see Figure 

2). Any PCB adjustments should be followed by a walk-test to verify detector 

coverage.

 

Do not touch the sensor surface as this could result in a detector malfunction. 

If necessary, clean the sensor surface using a soft cloth with pure alcohol.

Ensure that the unit’s front and back cover are tightly joined together without 

any spacing (around the rim of the unit) before tightening the screw, otherwise 

the weatherproof casing may be compromised and moisture may enter the 

unit.

Powering the Detector

1.  Insert three “AA” batteries into the battery holder while verifying polarity (see 

Figure 2).

2.  Insert the battery holder into the back cover and affix the battery cable to the battery 

connector on the PCB.

After connecting the battery cable, a power-up sequence will begin (lasting 

between 10 to 30 seconds). During this time, the red LED will flash and the 

detector will not detect an open zone or tamper.

Replacing the Batteries

1.  Disconnect the battery cable from the battery connector of the PCB. 

2.  Remove the battery holder from the back cover and remove the old batteries.

3.  Press and release the tamper switch to ensure that the unit has powered down.

Follow the steps outlined in “Powering the Detector” above.

Figure / Figura / Figure 1

Installation / Instalación / Installation

Figure / Figura / Figure 2

PCB Setup / Configuración de la PCI / Configuration de la carte de circuits imprimés

Technical Specifications

Compatibility:

MG5000, MG5500, MG-
6030, MG-6060, MG6130, 
MG6160, 1759MG, RTX3, 
MG-RCV3

Sensor type:

Dual Element Infrared (x2)

Sensor geometry: Rectangular
Operating temp:

-35°C to +50°C (-31°F to 
+122°F)

Power:

3 x “AA” alkaline batteries

RF frequency:

433

*

 or 868

**

MHz

Lens:

2nd generation Fresnel lens, 
LODIFF®, segments

Transmitter range: 35m (115ft) with MG6160 / MG6130

70m (230ft) with MG5000 / MG5500 / RTX3
typical in a residential environment

Tamper switch:

Yes

Detection speed‡: 0.2m to 3.5m/s (0.6ft to 11.5ft/s)
Battery life

:

4 years

* FCC ID: KDYMGPMD85

     

Canada: 2438A-MGPMD85

 

The PMD85W complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may 
not cause harmful interference, and (2) This device must accept any interference received, including interference that may 
cause undesired operation.

**

868MHz (only) is not UL approved.

Tested at 25°C.

 

Battery life expectancy will vary according to the amount of traffic (movement) the detector has processed and 

the temperature outdoors. A higher check-in time interval and higher traffic will lower battery life. In colder temperatures, the 
capacity of alkaline batteries is reduced.

‡ The UL approved detection speed is 0.76m/s (2.5ft/s).

Figure / Figura / Figure 3

PMD85W Pet Array Beam Pattern / Estructura de Tipo Paso de Mascotas PMD85W

 

Diagramme de lentilles Couloir pour animaux PMD85W 

Figure / Figura / Figure 4

PMD85L1 Horizontal Curtain Beam Pattern / Estructura de Tipo Cortina Horizontal 

PMD85L1 / Diagramme de lentilles Rideau horizontal

 

PMD85L1 

Figure / Figura / Figure 5

PMD85L2 Vertical Curtain Beam Pattern/ Estructura de Tipo Cortina Vertical 

PMD85L2 / Diagramme de lentilles Rideau vertical PMD85L2 

Detector Settings

Walk-testing

To put the detector into Walk-test Mode, open and close the cover. At 20°C (68°F), at 

the highest sensitivity setting and in Single Edge Processing mode, you should not be 

able to cross more than one complete zone (consisting of 2 beams, left and right 

sensor detecting elements) in the coverage area with any kind of movement; slow/fast 

walking or running. 

At the lowest sensitivity setting, the amount of movement required to generate an 

alarm is doubled. The approximate width of a full beam at 11m (35ft) from the detector 

is 1.8m (6ft). To walk-test, move across the detection path, not toward the detector.

After a power up, the detector will automatically enter Walk-Test mode for three 

minutes.

Signal Strength Test

In order to verify the receiver’s reception of the motion detector’s signal, perform a 

signal strength test before finalizing the installation of the PMD85. Prior to performing 

the test, make sure that the batteries have been inserted into the battery holder to 

power the detector. Also verify that the motion detector has been assigned to a zone. 

For more information on signal strength tests and zone programming, refer to the 

appropriate receiver’s 

Reference & Installation Manual

. If the transmission is weak, 

just moving the detector by a few inches can greatly improve the reception. If the 

signal is still weak, it is recommended that the detector be moved to another location.

Alive Software

If the motion detector transmits two alarm signals (LED on for 4 seconds) within a five 

minute period, the detector will fall into Energy Save mode where the detector will not 

transmit any alarm signals for approximately 3 minutes. Due to the motion detector’s 

Alive software, the red LED continues to flash to indicate a detection even when in 

Energy Save mode. Once the three-minute Energy Save mode ends, the detector will 

return to normal operation.

If the detector’s cover is removed and then replaced while in Energy Save 

mode, the first detection will trigger an alarm signal.

© 2007 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. 

One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 

5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply. 

Canadian and international patents may also apply. LODIFF® lens: patent #4,787,722 (U.S.). 

Digigard is a trademark or registered trademark of Paradox Security Systems Ltd. or its affiliates in Canada, 

the United States and/or other countries. 

LODIFF® is a registered trademark of Fresnel Technologies Inc.

Warranty: For complete warranty information on this product please refer to the Limited Warranty Statement 

found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance 

of all warranty terms and conditions.

Detector

Beam Pattern

PMD85W

Pet Array beam pattern (see figure 3)

PMD85L1

Horizontal Curtain beam pattern (see figure 4)

PMD85L2

Vertical Curtain beam pattern (see figure 5)

PMD85 SERIES

PRINTED IN CANADA - 01/2009  PARADOX.COM  PMD85-TI06

Instructions

Instrucciones

Outdoor Digital Dual-Optic High-

Performance PIR V1.01 

C

A

A

A

A

B

B

B

B

D

A

-Corner mount

-Montaje en esquina

-Montage en coin

B

  -Flat surface mount

-Montaje superficie plana

-Support pivotant

C

 -Swivel mount bracket

-Soporte de montaje giratorio

-Support pivotant

D

-PCB screw

-Vis de la carte de circuits imprimés

   -Tornillo de la PCI

Height Tab / Lengüeta de Altura / 

Onglet de hauteur

Align PCB height with the height tab of 

the back cover (see above).
Alinear la altura de la PCI con la 

lengüeta de altura de la cubierta 

trasera (ver arriba).
Aligner la hauteur de la carte de 

circuits imprimés avec l’onglet de 

hauteur du couvercle arrière (voir ci-

dessus).

A

B

C

D

2.1m 
(7ft/pi)

E

F

A

- Sensors / Sensores / 

Capteurs

B

- Battery connector 

- Conector de batería

- Connecteur de piles

C

- Anti-tamper switch

- Interruptor 

antisabotaje

- Interrupteur de 

sécurité

D

- Antenna / Antena / 

Antenne

E

- Detect LED

- LED de detección

- DEL de détection

F

- DIP switches 

- Interruptores DIP

- Commutateurs DIP 

G

- Sensitivity trimpot

- Potenciómetro

- Potentiomètre de 

sensibilité

Avoid bending, cutting 

or altering the antenna 

as this may affect signal 

transmission.

Éviter de courber, 

couper ou altérer 

l’antenne, car cela peut 

nuire à l’émission des 

signaux.

Evitar doblar, cortar o 

alterar la antena pues 

esto puede afectar la 

transmisión de la señal.

G

Co

ver

age

In

sta

lla

tio

n

Hei

ght Pe

Immu

nity

PMD85W

90°

11m x 11m
(35ft x 35ft)

2.1m
(7ft)

40kg
(90lbs)

PMD85L1
(Horizontal)

85°

11m x 11m
(35ft x 35ft)

1.1m
(3.6ft)

Multi/large
pet

PMD85L2
(Vertical)

5.64°

13m (43ft)
x 2 beams

2.1m
(7ft)

N/A

Ang

le

P

IW

R

7239,(:

6,'(9,(:

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

P

IW

7239,(:

6,'(9,(:

P

IW

P

IW

P

IW

P

IW

P

IW

7239,(:

6,'(9,(:

P

IW

P

IW

Step

 DIP 

Details

1

LED Setting

LED Feedback

On for 4 seconds: 

Motion has been detected

Flash every 8 seconds: Low battery trouble (checked 

every 12 hours)

Rapid Flash: 

Sending signal to receiver

DIP 

Switch 1

OFF 

= LED deactivated

ON 

= LED activated 

U

2

Signal 

Processing 

Mode

Single edge processing should be used in normal 

environments with minimal sources of interference. 

Dual Edge Processing provides better false alarm 

rejection if the detector is placed near sources of 

interference that can adversely affect it.

DIP 

Switch 2 

OFF =Dual 

edge 

ON =Single 

edge 

U

 

3

Sensitivity

The PMD85 features adjustable sensitivity. Adjust from 

1 (lowest sensitivity) to 10 (highest sensitivity)

U

.

Depending on the sensitivity setting, an alarm 

condition can be generated between 0.25 sec. 

(highest) and 2 sec. (lowest) after the actual 

movement.

Viewing Sensitivity Settings

Remove the cover to view how many times the LED 

flashes, then adjust the setting accordingly. The LED 

flashes a consecutive amount of times to show the 

setting. Thus if the sensitivity is set to 6, the LED 

flashes 6 times.

Trimpot

Turn clockwise 

=Increase sensitivity

Turn counterclockwise  =Decrease sensitivity

The sensitivity trimpot is fragile. Do not 

overtorque.

U

= default settings

DIP switches 3 and 4 are reserved for future use.