 M100 CDMA 

plus

 

www.maestro-wireless.com

  

[email protected]

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

M100 CDMA 

plus

  

 
 

 

 

Quick Start Guide  

Version 1.4 Beta

 

Firmware R7.52.0.A3 

SmartPack_097k_SL3010T 

Summary of Contents for M100 CDMA plus

Page 1: ...M100 CDMA plus www maestro wireless com support maestro wireless com 1 M100 CDMA plus Quick Start Guide Version 1 4 Beta Firmware R7 52 0 A3 SmartPack_097k_SL3010T...

Page 2: ...no liability for damage incurred directly or indirectly from errors omissions or discrepancies between the modem and the manual This software solution or application is provided on an as is basis No...

Page 3: ...elated documents 9 Chapter 4 10 Hardware installation 10 Mounting the modem 10 Connecting the external antennas SMA type 10 Connecting the modem to external device 11 Connecting the DC power supply 11...

Page 4: ...B male to USB A male cable ACC CA42 19 Power cord with fuse ACC CA10 19 Penta band L shape antenna ACC A11 19 Penta band antenna ACC A17A 20 Penta band antenna ACC A03 20 DIN rail mount ACC DIN 20 DB1...

Page 5: ...the difference between M100 2G M100evo M100 3G and M100 CDMA plus GPIO type on the 4 pin Micro Fit connector Below known issues on M100 CDMA plus DCD DSR DTR signals are not currently available on the...

Page 6: ...ge 5 32V Rated current 650mA Typical current consumption Mode 5V 12V 32V IS 2000 PCS 1900MHz 642mA 233mA 101mA IS 2000 cellular 800MHz 520mA 217mA 91mA IS 95B PCS 1900MHz 582mA 232mA 99mA IS 95B cellu...

Page 7: ...European directive EN60590 if the ambient temperature exceeds or might exceed 65 C it is required that the installer Avoid physical contact with the Maestro 100 3G when the temperature exceeds 65 C Ad...

Page 8: ...stro wireless com support maestro wireless com 8 Front label Back label Packing Bulk carton box of 50 pieces Each M100 CDMA plus in single plastic bag without any accessories Overall size 522mm x 212m...

Page 9: ...tion details neither the common 3GPP AT command list for more information please refer to the following documentations available on our website Maestro M100 Series SmartPack User manual version3 or hi...

Page 10: ...h SMA male connector on the modem make sure antennas are tightly secured Select a CDMA antenna with the right CDMA frequency and an impedance of 50 incorrect antenna will affect communication and even...

Page 11: ...le Connecting the DC power supply If delivered with the power cord accessory detailed on page 20 use the open ending of the power cord to connect a DC supply Refer to the following for power supply re...

Page 12: ...with the AT command AT CSQ wait 20s after it is powered up to have a stable value A good signal is a value 11 for the 1st parameter of the command result If signal is below 11 it is recommended to mo...

Page 13: ...will also create a shortcut on your desktop Using the Maestro Configuration Software The window shown on Figure 5 on the following page will appear when the application starts you need to enter your C...

Page 14: ...Modem Status page see Figure 6 displays the reception signal strength RSSI refreshed every five seconds your network name as well as the revision number for the embedded application and firmware The...

Page 15: ...M100 CDMA plus www maestro wireless com support maestro wireless com 15 Figure 7 Terminal page Maestro Configuration Software...

Page 16: ...female connector fits active or passive GPS antenna with impedance of 50 Note Make sure to install CDMA and GPS antennas with an angle of at least 90o to avoid disturbance Mini USB B female connector...

Page 17: ...Output 12 RTS Request To Send Input 13 RI Ring Indicator Output 14 RESET Input Pull low for 100ms to reset module require 5 7s to reboot 15 4 pin Micro Fit Molex connector Power and input Figure 8 Pin...

Page 18: ...s com support maestro wireless com 18 Digital inputs wiring diagram Example of DI1 used as input to sense a switch Output needs to be open when using as an input Input is high when voltage is over 3V...

Page 19: ...led Cable length 50cm Make sure the current given to the USB connectors from computer is sufficient especially while in 3G communication Using USB X Cable may alter performance of the M100 3G if used...

Page 20: ...quency bands 1575 42MHz Gain 26dB 46 5 x 46 5 x 12 5 mm Mounting magnetic base Material ABS Polarization Linear Cable length 3m RG 174 U Switching Power Adaptor Industrial grade 1 25 A with NEMA 2 Pin...

Page 21: ...Os from their application else the Maestro SmartPack will control GPIOs through SmartPack AT commands Inputs are mapped in OpenAT to GPIO1 for DI1 GPIO3 for DI2 To setup DI1 as an input type AT WIOM 1...

Page 22: ...that the CTS and DTR pins of the serial port are not connected together The modem does not respond to the terminal program Check if the RS 232 cable has been properly connected Check if your program h...

Page 23: ...meter has to be at least 15 for normal communication Receiving an incoming call RING An incoming call is waiting ATA OK Answer the call Make a call ATD1234567 OK Communication established Don t forget...

Page 24: ...M100 CDMA plus www maestro wireless com support maestro wireless com 24...