Macnaught MX Series Manual Download Page 1

 

Page 1 of 32

 

Intrinsically Safe with Simple Apparatus PCB

 

MX SERIES

 

OVAL GEAR FLOWMETER 

 

MXEX

-

IS

-

INST

 

Rev 1

 

04/2022

 

To the Owner

 

Please read and retain this instruction manual to assist 

you in the operation and maintenance of this product.

 

 

The  manual  contains  operating  and  maintenance     

instructions  for  the  MX

-

Series  Flow  Meters  with  Ex 

outputs. This covers port sizes from 

1/4” 

to 

4”.

 

 

Refer to separate instruction manual for information on 

operating  modes  and  features  of  LCD  displays.     

Contact  local  representative  or  distributor  for  further 

assistance. 

 

  

 

This  Flow  Meter  has  incorporated  the  oval  gear      

principle  into  its  design.  Exceptional  repeatability  and 

high  accuracy  over  a  wide    range  of    fluid  viscosities 

and flow rates are features of the oval gear design. 

 

 

 

With a low pressure drop and high pressure ratings, 

oval  gear  flow  meters  are  suitable  for  gravity  and    

(in

-

line) pump applications.

 

 

Macnaught offer a comprehensive set of web based 

support  materials  to  complement  this  instruction   

manual.

 

 

Access  the  Instruction  manual  by  scanning  below 

QR code.

 

www.macnaught.com.au

 

Summary of Contents for MX Series

Page 1: ...on operating modes and features of LCD displays Contact local representative or distributor for further assistance This Flow Meter has incorporated the oval gear principle into its design Exceptional...

Page 2: ...em Page 9 Flow meter Specifications Page 10 Simple Apparatus PCB Page 11 Intrinsically Safe Display ERX Fx Page 12 13 Intrinsically Safe Display ERAX Gx Page 14 15 Intrinsically Safe Batch Controller...

Page 3: ...with high risk of ignition explosion Ensure no source of iron oxides are available within the Ex zone where the flow meter is installed In the event a leakage on the flow meter is observed process mus...

Page 4: ...resulting from alterations to the product Only sound IP67 cable glands must be on the register housing to pull signal cable out of the register Installation must be carried out by qualified and train...

Page 5: ...the housing surface by friction must be avoided The devices must not be dry cleaned If you feel an electric shock while using the meter stop dispensing immediately Identify and correct the problem be...

Page 6: ...rientation as long as the meter shafts are in a horizontal plane as per the picture Incorrect installation can cause premature wear of meter components Do not over tighten meter connections 7 It is im...

Page 7: ...tified by running a metal object over the face of the rotor Placed both the rotors at 90 to each other onto the shafts Spin them to check if they move freely If not repeat the process Active Rotor Pla...

Page 8: ...PRESENTATION OF FLOWMETER AND DISASSEMBLED PARTS Rotors Chamfer Area FIG 6 For MX06 and MX09 meters the flat side of rotors with chamfer on edges face upward when placed on cap and shaft assembly of m...

Page 9: ...eads MX06 MX100 3 BSP and NPT port connection for MX100 2 NPT threads 3 ANSI 150 Flanges MX25 MX100 4 JIS 10k Flanges 5 DIN PN 16k Flanges 6 BSP Rc Threads MX06 MX09 MX12 and MX25 Rotor Type P PEEK MX...

Page 10: ...235 LPM 4 to 62 GPM 10 to 250 LPM 2 6 to 66 GPM MX50 15 to 500 LPM 4 to 130 GPM 15 to 500 LPM 4 to 130 GPM MX75 60 to 600 LPM 17 to 170 GPM 20 to 733 LPM 5 to 194 GPM MX100 220 to 1000 LPM 60 to 250 G...

Page 11: ...isplay Both reed switch input circuits of the MX1R IS module are suitable for use as simple apparatus in type of protec tion intrinsic safety Ex ia IIC only for connection to certified intrinsically s...

Page 12: ...real time indication of Flow rate total resettable and accumulat ed total non resettable This display is IECEx ATEX CSA Canada and FM USA certified Locally mount to Macnaught Oval Gear Flowmeter with...

Page 13: ...Off Green Amber 33 BL BRIGHTNESS 1 5 4 POWER MANAGEMENT 41 LCD UPDATE Fast 1 sec 3 sec 15 sec 30 sec off 42 BATTERY MODE Operational Shelf 5 FLOWMETER 51 SIGNAL REED_LP 6 OTHERS 61 TYPE MODEL F012 Do...

Page 14: ...ation of Flow rate total resettable and accumulat ed total non resettable The output include a 4 20mA and scaled pulse output This display is IECEx ATEX CSA Canada and FM USA certified Locally mount t...

Page 15: ...mL L m mg g kg ton GAL bbl lb cf REV no unit scf Nm NL P 22 time unit sec min hour day 23 decimals 0 1 2 3 Ref displayed value 24 k factor 0 000010 9 999 999 As per Flowmeter report 25 decimals k fac...

Page 16: ...B and Intrinsically Safe display is IP67 rated Macnaught type Hx display uses Fluidwell Intrinsically Safe display electronic PN F030 P HR OT PC PD XI ZB Wiring Instructions reference www fluidwell co...

Page 17: ...TAL 11 UNIT L m kg lb GAL USGAL bbl no unit 12 DECIMALS 0 1 2 3 Ref displayed value 13 K FACTOR 0 000010 9 999 999 As per Flowmeter report 14 DECIMALS K FACTOR 0 6 This setting depend upon setting 24...

Page 18: ...EN1092 1 40A 10K JIS B 2220 240 mm MX50 40 Nm 2 150 LB B16 5 DN50 PN 16 EN1092 1 50A 10K JIS B 2220 264 mm 1 The locknut gasket O ring and retaining ring to be fitted as shown in the below picture Mak...

Page 19: ...TS 5 ROTORS 6 METER CAP 7 METER CAP SCREWS 8 METER COMPONENTS ITEM NO METER COMPONENTS ITEM NO METER BODY 1 CIRCLIP 7 ROTOR SHAFTS 2 METER CAP BOLTS 8 ROTORS 3 FLANGE SEALS 9 METER CAP O RING 4 PROCES...

Page 20: ...fications for maximum viscosity Meter reading inaccurate a Fluid flow rate is too high or too low b Air in fluid c Excess wear caused by incorrect instal lation a See specifications for minimum and ma...

Page 21: ...MX19S MX25S MX40S MX50S MX75S MX100S METER BODY AL AL AL AL AL METER CAP AL AL AL AL AL ROTORS SS 316 SS 316 SS 316 PEEK AL PEEK AL HIGH VISCOSITY ROTORS SS 316 SS 316 AL AL ROTOR SHAFTS SS 316 SS 316...

Page 22: ...SEAL MX75P MX100P Category S ROTOR KIT SEAL KIT Standard High Viscosity PEEK MX06S MXS 06S ROTOR MXS 06S SEAL MX09S MXS 09S ROTOR MXS 09S HVROTOR MXS 09S SEAL MX12S MXS 12S ROTOR MXS 12S HVROTOR MXS...

Page 23: ...Page 23 of 32 PRESSURE DROP v VISCOSITY 100 50...

Page 24: ...49 N A MX19 100 112 37 62 N A MX25 100 112 45 75 240 MX40 120 137 61 120 240 MX50 140 153 72 123 264 FLANGE TYPES ANSI flanges 150 and DIN PN 16 flanges are raised faced RF while JIS 10k flanges are f...

Page 25: ...Page 25 of 32 DIMENSIONS Flowmeter Registers...

Page 26: ...8 MX12 6 5 5 47 69 81 47 73 113 6 49 M5x0 8 MX19 7 6 6 61 85 100 61 95 143 6 62 M6x1 0 MX25 7 6 6 61 85 100 61 95 143 6 75 M6x1 0 A Wall Mount Holes 4 B SS Countersunk screws to be supplied with the w...

Page 27: ...MX06 MX50 Meters A B C D MX06 45 M5 x 0 80 45 42 MX09 45 M5 x 0 80 45 42 MX12 47 M5 x 0 80 47 49 MX19 61 M6 x 1 00 61 62 MX25 61 M6 x 1 00 61 75 MX40 80 M8 x 1 25 80 102 MX50 80 M8 x 1 25 100 123 B Mo...

Page 28: ...Page 28 of 32 EU Declaration of Conformity...

Page 29: ...Page 29 of 32 EU Declaration of Conformity...

Page 30: ...Page 30 of 32 Declaration of Conformity Simple Apparatus PCB...

Page 31: ...does not apply to some of Macnaught s products we sup port its policy and ask you to be aware of how to dispose of this product The crossed out wheelie bin symbol illustrated and found on our product...

Page 32: ...of 32 Note This product should be disposed of according to all applicable local and national government environment regulations and Macnaught USA 614 S Ware Blvd Tampa FL 33619 813 628 5506 Macnaught...