Macnaught M Series Instruction Manual Download Page 1

 

Page 1 of 20 

INSTRUCTION  MANUAL— ‗M‘ Series 006/009 Meters

 

To the Owner 

OVAL GEAR FLOWMETER 

ELECTRONIC MODEL 006/009 (¼‖) 

PLEASE READ THIS SAFTEY INFORMATION 

CAREFULLY BEFORE USE.

 

 

Read and retain this instruction manual to assist you 

in the operation and maintenance of this product. 

 

If you have any problems with the meter, refer to the  

maintenance and trouble shooting sections of  this 

manual. 

 

This manual contains connection and operating  in-

structions for meters with Pulse outputs. 

   

Models with a Liquid Crystal Display have an addi-

tional LCD instruction manual  supplied. If  you need 

further assistance, contact your local representative 

or distributor for advice. 

This Flow Meter has incorporated the oval rotor prin-

cipal into its design. This has proven to be a reliable 

and highly accurate method of measuring  flow. 

 

Exceptional repeatability and high accuracy over a 

wide  range of  fluid viscosities and flow rates are 

features of the oval rotor design. With a low pressure 

drop and high pressure rating oval rotor flow meters 

are suitable for both  gravity  and  pump (in  line) 

applications. 

 

This instruction manual covers pulse meters con-

structed in Aluminium or Stainless Steel.   

INST-006/009P_R13 

05/2020 

Summary of Contents for M Series

Page 1: ...Crystal Display have an addi tional LCD instruction manual supplied If you need further assistance contact your local representative or distributor for advice This Flow Meter has incorporated the oval...

Page 2: ...ulser Specifications Page 5 Page 6 Service Troubleshooting Guide Page 11 Spare Parts Kits Page 12 Wetted Parts Page 16 General Pressure Drop Graphs Page 17 Dimensional Diagrams Page 18 19 Wiring Instr...

Page 3: ...Reed switches or Hall Effect sensors A signal is generated which is then sent by the Pulse Circuit Board PCB to the relevant LC display or receiving instrument Installation Procedure 1 It is recommen...

Page 4: ...otate the rotors by hand to ensure correct engagement 2 Fit the O Ring Item 4 into the O Ring groove in the meter body Item 1 3 Fit the top cap assembly Item 5 fit the legend plate Item 6 into correct...

Page 5: ...uel and Oil M Industrial Range 500 kPa 5500 kPa 5500 kPa 5500 kPa 75 PSI 800 PSI 800 PSI 800 PSI Accuracy of Reading 0 5 1 Conforms to Directive 97 23 EC Cat 1 Pulser Board Sensor Specifications The f...

Page 6: ...ct Sensor Hall Effect sensor is a 3 wire device which triggers by magnet inside the rotors as they spin This sensor is NPN type current sinking open collector The sensor circuit is equipped with a 4 7...

Page 7: ...y display signal by including the following LCD displays with your flow meter These may be fitted to the meter or remote wall mount types DRA Small display with analogue output module Remote or Meter...

Page 8: ...only valid for flowmeters fitted with DIN connector Wiring instructions Reed Hall Module Pin designation M12 male connector Contact designation M12 cable Schematic diagram Schematic diagram Wiring ins...

Page 9: ...If fitted with DIN connector Wiring instructions Dual Reed Module Pin designation M12 male connector Contact designation M12 cable Schematic diagram Schematic diagram Note The below wiring instructio...

Page 10: ...cast nickel plated Rated voltage current 60v 4A Contact resistance Max 5 m Ambient temperature plug and socket 25 C 90 C Technical Specifications cable Core Number 5 core Core colours brown white blu...

Page 11: ...n fluid c Excess wear caused by incorrect installa tion a See specifications for minimum and maximum flow rates b Bleed air from system c Check meter body and rotors Replace as required Refer to insta...

Page 12: ...KIT F009 DIN V RKIT S009 DIN V RKIT S009 DIN V Reed Hall Effect PKIT F006 009 RH PKIT S006 009 RH PKIT M006 009 RH Pulser KIT PKIT CR006 009 RH Dual Reed Switch PKIT F006 009 RR PKIT S006 009 RR PKIT...

Page 13: ...s e g PKit F006 2 Pulser Cap 1 5 6 Bolts 4 7 Seal O ring 1 4 Kit Components Item No Part Description 1 Meter Body 2 Active Rotor 3 Neutral Rotor 4 O Ring 5 Meter Cap 6 Legend Plate 7 Meter Cap Screws...

Page 14: ...for both 006 and 009 meters SKit Type Size P F 006 1 S 2 Customer Model Number Seal Kit for Models M F S and CR If fitted with cable Order Number Components Qty Items e g SKit F006 P Meter Body O Ring...

Page 15: ...1 S 2 Kit Components Coding Sequence RKit Type Size S P NOTE Where P denotes pulse meter Rotor Kit for Models M F S and CR If fitted with DIN connector Customer Model Number Order Number Components Q...

Page 16: ...el 006 Model 009 Component Type F Type S Type M Type CR Meter Body Al Al SS PPS Meter Cap Al Al SS PPS Rotor Shafts SS SS SS Hast C Rotors Standard SS SS SS PPS High Temp SS High Viscosity SS SS SS Ro...

Page 17: ...Page 17 of 20 Pressure Drop v s Viscosity 100 50 25 10 5 100 50...

Page 18: ...Page 18 of 20 Meter Dimensions 006 Dimensions of DR DRA register If meter 006 is fitted with one of these...

Page 19: ...Page 19 of 20 Meter Dimensions 009 Dimensions of DR DRA register If meter 009 is fitted with one of these...

Page 20: ...s signifies that this product should not be disposed of in general waste or landfill Please contact your local dealer national distributor or Macnaught Technical Services for information on product di...