TROUBLE SHOOTING GUIDE 

PRODUCT SPECIFICATIONS: 

For Warranty Terms and Conditions see macnaught.com.au

 

 

For a list of Australian Service Centres see macnaught.com.au

  

* When tested with lubrication oil @ 25°C. Allowances should be made for changes to these parameters. 

* Accuracy 

+/- 1% 

Batch Total 

999.9 

Accumulative Total 

999999.9 

Wetted components: 

Acetal, aluminium, nitrile (NBR), mild steel 

Flow Range: 

1-30 litres/minute (0.26-8 US gal/min) 

Max. working pressure: 

6900 kPa / 1000 psi / 69 Bar 

Inlet thread - Gun 

½” BSPT 

Outlet thread: -Meter 

½” BSPP 

Operating temperature: 

-10°C (14°F) to +55°C (131°F) 

Weight (approx): 

1.75kg  

Note:  

This product should be disposed of according to all applicable local 
and national government environment regulations and guidelines.

 

 

TROUBLE CAUSE 

REMEDY 

Inaccurate 

a) Measuring chamber dirty or clogged 

a) Clean measuring chamber (ref disassembly and 

reassembly section) 

  

b) Air in system 

b) Eliminate any leaks and purge air from the system 

Low flowrate 

a) Measuring chamber is dirty or clogged  a) Clean measuring chamber (ref disassembly and 

reassembly section) 

  

b) Measuring chamber is dirty or clogged  b) Clean measuring chamber (ref disassembly and 

reassembly section) 

  

c) Damaged plunger seal 

c) Replace damaged plunger seal 

Constant oil leak from the nozzle 

a) Damaged plunger seal  

a) Replace plunger seal ( check for damage ) 

Intermittent drip from the nozzle 

b) Dirt in the nozzle 

b) Remove the nozzle and blow out any dirt particles,  

  

  

replace if necessary. 

Oil leak from the lever assembly area 

a) Damaged o’rings  

a) Replace damaged o’rings 

Oil leaking from the swivel inlet 

a) Damaged o’ring or swivel 

a) Replace swivel   