78
SeCtion b
SoFtware Manual
RetuRn to toC
MaCe HydRoMaCe 3000
Product Manual
79
RetuRn to toC
23.2 Serial Interface Settings
- continued
Notes:
1. Register byte order is big-endian
2. Float values are formatted according to IEEE 744 32-bit representation
3. Flow total has a range from 0 to 999999.9
4. Registers corresponding to parameters, which are not configured to be measured or calculated,
contain random values.
5. HM 3000 channel outputs are in order of channel configuration as per HM 3000 settings. Refer to
Chapter 21.2.1 for ordering configured channels.
WARNING: The outputs listed in this table are for illustrative purposes only.
SUPPORTED FUNCTION CODES:
Command
Code (hex)
Sub-code (dec)
Read Input Registers
04
Diagnostics
08
00-04,10-18
REgISTER MAP:
Parameter HM 3000 Output
5
Type Size (bits) # Registers Register(s)
Channel 1
Velocity
float
32
2
40001-40002
Channel 2
Depth
float
32
2
40003-40004
Channel 3
Flow Rate
float
32
2
40005-40006
Channel 4
Total
float
32
2
40007-40008
Channel 5
Velocity I/O
float
32
2
40009-40010
Channel 6
Depth 4-20mA
float
32
2
40011-40012
Channel 7
Binary On/Off
float
32
2
40013-40014
Channel 8
Conductivity
float
32
2
40015-40016
Channel 9
-
float
32
2
40017-40018
Channel 10
-
float
32
2
40019-40020
Channel 11
-
float
32
2
40021-40022
Channel 12
-
float
32
2
40023-40024
Channel 13
-
float
32
2
40025-40026
Channel 14
-
float
32
2
40027-40028
Channel 15
-
float
32
2
40029-40030
Channel 16
-
float
32
2
40031-40032
Channel 17
-
float
32
2
40033-40034
Channel 18
-
float
32
2
40035-40036
Channel 19
-
float
32
2
40037-40038
Channel 20
-
float
32
2
40039-40040
23.2.3 SDI-12 Mode
The SDI-12 implementation complies with V1.3 of the SDI-12 specification.
Configurable parameters are:
• Address (‘0’-‘9’, ‘A’-‘Z’, ‘a’-‘z’)
• Which measurement results to provide
On receiving an SDI-12 Measurement command, the FloSI replies with
notification that the measurement results are immediately available. Upon
receiving a Send Data command, the FloSI returns the currently available
result data which it has been configured to provide.
THE FOLLOWINg SDI-12 COMMANDS ARE SUPPORTED:
Name
Command
Response
Acknowledge active
a!
a<CR><LF>
Send Identification
aI!
a13MACE P/FloSI3100#nnnnn<CR><LF>
Address Query
?!
a<CR><LF>
Start Measurement
aM!
a000n<CR><LF>
Start Measurement and
aMC!
a000n<CR><LF>
Request CRC
a<values><CR><LF>
Send data
aD0!
to
aD9!
or
a<values><CRC><CR><LF>
Additional Measurements
aM1!
to
aM9!
a0000<CR><LF>
Additional Measurements
aMC1!
to
aMC9! a0000<CR><LF>
and Request CRC
Start Verification
aV!
a0000<CR><LF>
Start Concurrent Measurement
aC!
a000n<CR><LF>
Start Concurrent Measurement
aCC!
a000n<CR><LF>
and Request CRC
Additional Concurrent
aCC1!
to
aCC9!
a0000<CR><LF>
Measurements
Continuous Measurement #0
aR0!
a<values><CR><LF>
Continuous Measurements #1
to
9 aR1!
to
aR9!
a<CR><LF>
Continuous Measurement #0
aRC0!
a<values>< CRC><CR><LF>
and Request CRC
Continuous Measurements #1
to
9 aRC1!
to
aRC9!
a< CRC><CR><LF>
and Request CRC