Connecting to an HVFlo XCi device
Connecting to the device using the communications port
1. Unscrew the cover from the communications port.
2. Connect a MACE USB Communication Cable (Part No. 850-363) between the USB port of the
computer and the communications port of the HVFlo XCi device located on the left underside of the
enclosure.
3. With FloCom
+
running, click "
Connect>to Flo3 device
" and the "
Connect to Device
" dialogue will
open. Enter the password which has been set in the unit and select "
Continue
". (The default
password is
superid
)
4. The main menu of FloCom
+
that includes the device status summary screen is now visible as shown
below.