214658
100
Revision A
Adjusting Threshold for Drop Rate Valve (John Deere 60 Series)
This procedure explains how to adjust the point at which the restrictor valve opens and allows full flow to lift
cylinders.
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
1026337
A
B
C
D
Figure 6.55: John Deere Combine Display
1.
Press DIAGNOSTIC button (A) on monitor. DIA
appears on the monitor.
2.
Press UP button (B) until EO1 appears on monitor and
press ENTER (C). This is header adjustment.
3.
Press UP (B) or DOWN button (D) until 114 is displayed
on top portion of monitor. This is the setting that adjusts
when fast drop rate starts with respect to dead band.
NOTE:
The default setting is 100. Ideal operating range is
typically between 60 and 85.
4.
Press ENTER (C) to select 114 as fast drop rate (this
will allow you to change first digit of number sequence).
1026339
A
D
C
B
Figure 6.56: John Deere Combine Display
5.
Press UP (A) or DOWN (B) until desired number is
displayed, then press CAL button (C). This will bring
you to second digit. Repeat this procedure until desired
setting is achieved.
6.
Press ENTER (D) to save changes.
NOTE:
The numbers depicted on displays in these illustrations
are for reference purposes only; they are not intended
to represent specific settings for your equipment.