214657
146
Revision A
Figure 4.105: New Holland Combine Display
3.
Select HEADER AUTOFLOAT, and press ENTER.
4.
Use up and down navigation keys to move between
options, and select INSTALLED.
Calibrating Auto Header Height Control (New Holland CR/CX Series)
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator
’
s manual for updates.
CAUTION
Check to be sure all bystanders have cleared the area.
Check following conditions before starting header calibration procedure:
•
The header is attached to combine.
•
The combine is on level ground, with header level to ground.
•
The engine is running.
•
The combine is not moving.
•
No faults have been received from Header Height Controller (HHC) module.
•
Header/feeder is disengaged.
•
Lateral float buttons are
NOT
pressed.
•
ESC key is
NOT
pressed.
To calibrate the AHHC, follow these steps:
1.
Select CALIBRATION on combine display, and press right arrow navigation key to enter information box.
Summary of Contents for PW8