MAC215990
248
Revision A
4.3
Lubrication
Grease zerk locations are marked on the machine by decals showing a grease gun and the greasing interval, which will be
specified in terms of hours of header operation.
1001336
Figure 4.3: Grease Interval Decal
Refer to the inside back cover for information on the
recommended lubricants.
Log the header
’
s hours of operation. Use the maintenance
record provided in this manual to keep track of what
maintenance procedures have been performed on the header,
and when. For more information, refer to
4.3.1
Lubrication Intervals
The lubrication intervals are specified in terms of hours of header operation. Maintaining accurate maintenance records is
the best way to ensure these procedures are performed in a timely fashion.
Every 10 Hours
Daily maintenance is required to keep your machine operating at peak performance. It also allows you to do a visual
inspection of the machine that may help identify issues early.
Use high temperature extreme pressure (EP2) performance grease with 1% max molybdenum disulphide (NLGI Grade 2)
lithium base unless otherwise specified.
1034116
A
Figure 4.4: Feed Draper Drive Roller
IMPORTANT:
When greasing, clear any debris and excess grease from around
the bearing and bearing housing. Inspect the condition of the
bearing and bearing housing. Grease the feed draper drive roller
bearing until grease comes out of the seal. Wipe any excess
grease from area after greasing.