262171
276
Revision A
ϭϬϰϮϭϬϴ
A
Figure 5.172: Knife Adjust Page
2.
Use KNIFE SPEED arrows (A) to adjust the strokes per
minute (spm) value.
NOTE:
For information and suggested knife speed settings for a
variety of crops and conditions, refer to the header
operator
’
s manual.
Adjusting Knife Speed and Pressure Alarms
The knife alarm features in the HarvestTouch
™
Display can inform the Operator when knife speed or pressure exceed a
specified range.
ϭϬϰϮϭϬϮ
A
Figure 5.173: HarvestTouch
™
Display - Header
Run Screen
1.
To set either of the knife alarms, engage the header to
display header run screen 1, and then press KNIFE
SETTINGS icon (A).
ϭϬϰϮϭϬϵ
A
Figure 5.174: Knife Adjust Page
2.
To adjust the KNIFE SPEED ALARM set point, press
arrows (A) until the desired value is shown.
NOTE:
The knife speed alarm alerts the Operator when knife
speed drops below a specified percentage of preset knife
speed. In the example shown, the alarm will sound if knife
speed drops below 1120 spm. The default is 70% and the
adjustment range is 50
–
90%.